Performance evaluation of an under‐mattress sleep sensor versus polysomnography in > 400 nights with healthy and unhealthy sleep

Consumer sleep trackers provide useful insight into sleep. However, large-scale performance evaluation studies are needed to properly understand sleep tracker accuracy. This study evaluated performance of an under-mattress sensor to estimate sleep and wake versus polysomnography in a large sample, including individuals with and without sleep disorders and during day versus night sleep opportunities, across multiple in-laboratory studies. One-hundred and eighty-three participants (51%/49% male/female, mean [SD] age = 45 [18] years) attended the sleep laboratory for a research study including simultaneous polysomnography and under-mattress sensor (Withings Sleep Analyser) recordings. Epoch-by-epoch analyses determined accuracy, sensitivity and specificity of the Withings Sleep Analyser versus polysomnography. Bland-Altman plots examined bias in sleep duration, efficiency, onset-latency, and wake after sleep onset. Overall Withings Sleep Analyser sleep-wake classification accuracy was 83%, sensitivity 95% and specificity 37%. The Withings Sleep Analyser significantly overestimated total sleep time (48 [81] min), sleep efficiency (9 [15]%) and sleep-onset latency (6 [26] min), and underestimated wake after sleep onset (54 [78] min). Accuracy and specificity were higher for night versus daytime sleep opportunities in healthy individuals (89% and 47% versus 82% and 26%, respectively, p < 0.05). Accuracy and sensitivity were also higher for healthy individuals (89% and 97%) versus those with sleep disorders (81% and 91%, p < 0.05). Withings Sleep Analyser performance is comparable to other consumer sleep trackers, with high sensitivity but poor specificity compared with polysomnography. Withings Sleep Analyser performance was reasonably stable, but more variable in daytime sleep opportunities and in people with a sleep disorder. Contactless, under-mattress sleep sensors show promise for accurate sleep monitoring, noting the tendency to over-estimate sleep particularly where wake time is high.

Authors

Institutions

Publication Details

Journal
Journal of Sleep Research
Published
2025-02-28
DOI
https://doi.org/10.1111/jsr.14480
Citations
11
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
12.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance evaluation of an under‐mattress sleep sensor versus polysomnography in > 400 nights with healthy and unhealthy sleep

Jack Manners, Hannah Scott, Bastien Lechat, Danny J. Eckert et al.
11 citations
Journal of Sleep Research
Obstructive Sleep Apnea Research
12.81
article

Performance evaluation of an under‐mattress sleep sensor versus polysomnography in > 400 nights with healthy and unhealthy sleep

Jack Manners, Hannah Scott, Bastien Lechat, Danny J. Eckert, Eva Kemps, Peter Catcheside
article en
11 citations

Abstract

Consumer sleep trackers provide useful insight into sleep. However, large-scale performance evaluation studies are needed to properly understand sleep tracker accuracy. This study evaluated performance of an under-mattress sensor to estimate sleep and wake versus polysomnography in a large sample, including individuals with and without sleep disorders and during day versus night sleep opportunities, across multiple in-laboratory studies. One-hundred and eighty-three participants (51%/49% male/female, mean [SD] age = 45 [18] years) attended the sleep laboratory for a research study including simultaneous polysomnography and under-mattress sensor (Withings Sleep Analyser) recordings. Epoch-by-epoch analyses determined accuracy, sensitivity and specificity of the Withings Sleep Analyser versus polysomnography. Bland-Altman plots examined bias in sleep duration, efficiency, onset-latency, and wake after sleep onset. Overall Withings Sleep Analyser sleep-wake classification accuracy was 83%, sensitivity 95% and specificity 37%. The Withings Sleep Analyser significantly overestimated total sleep time (48 [81] min), sleep efficiency (9 [15]%) and sleep-onset latency (6 [26] min), and underestimated wake after sleep onset (54 [78] min). Accuracy and specificity were higher for night versus daytime sleep opportunities in healthy individuals (89% and 47% versus 82% and 26%, respectively, p < 0.05). Accuracy and sensitivity were also higher for healthy individuals (89% and 97%) versus those with sleep disorders (81% and 91%, p < 0.05). Withings Sleep Analyser performance is comparable to other consumer sleep trackers, with high sensitivity but poor specificity compared with polysomnography. Withings Sleep Analyser performance was reasonably stable, but more variable in daytime sleep opportunities and in people with a sleep disorder. Contactless, under-mattress sleep sensors show promise for accurate sleep monitoring, noting the tendency to over-estimate sleep particularly where wake time is high.

Journal of Sleep ResearchVol. 34(6)
Flinders University (AU), Adelaide Institute for Sleep Health (AU)
Defence Science and Technology Group
No poverty
Openalex Percentile: Top 1%
Obstructive Sleep Apnea Research
12.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.