Unexpected postoperative incidental recurrent laryngeal nerve palsy post total thyroidectomy after intraoperative nerve monitoring (overstimulation and fatigability): a case report
Visual identification of the recurrent laryngeal nerve is the gold standard for nerve protection. We recommend the use of nerve monitoring as an adjunct in challenging cases but not in routine settings, as it does not decrease the incidence of injuries compared with visualization alone in our experience.