Bowel tracking for MR-guided radiotherapy: simultaneous optimization of small bowel imaging and tracking

<i>Objective</i>. The small bowel is one of the most radiosensitive organs-at-risk during radiotherapy in the pelvis. This is further complicated due to anatomical and physiological motion. Thus, its accurate tracking becomes of particular importance during therapy delivery, to obtain better dose-toxicity relations and/or to perform safe adaptive treatments. The aim of this work is to simultaneously optimize the MR imaging sequence and motion estimation solution towards improved small bowel tracking precision during radiotherapy delivery.<i>Approach</i>. An MRI sequence was optimized, to adhere to the respiratory and peristaltic motion frequencies, by assesing the performance of an image registration algorithm on data acquired on volunteers and patients. In terms of tracking, three registration algorithms, previously-employed in the scope of image-guided radiotherapy, were investigated and optimized. The optimized scan was acquired for 7.5 min, in 18 patients and for 15 min, in 10 volunteers at a 1.5 T MRL (Unity, Elekta AB). The tracking precision was evaluated and validated by means of three different quality assurance criteria: Structural Similarity Index Measure (SSIM), Inverse Consistency (IC) and Absolute Intensity Difference.<i>Main results</i>. The optimal sequence was a balanced Fast Field Echo, which acquired a 3D volume of the abdomen, with a dynamic scan time of 1.8 s. An optical flow algorithm performed best and which was able to resolve most of the motion. This was shown by mean IC values of<1 mm and a mean SSIM>0.9for the majority of the cases. A strong positive correlation (<i>p</i> <0.001) between the registration performance and visceral fat percentage was found, where a higher visceral fat percentage gave a better registration due to the better image contrast.<i>Significance</i>. A method for simultaneous optimization of imaging and tracking was presented, which derived an imaging and registration procedure for accurate small bowel tracking on the MR-Linac.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-02-28
DOI
https://doi.org/10.1088/1361-6560/adbbac
Citations
3
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
5.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bowel tracking for MR-guided radiotherapy: simultaneous optimization of small bowel imaging and tracking

Astrid L.H.M.W. van Lier, Cornel Zachiu, Bas W. Raaymakers, Saskia L.C. Damen
3 citations
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
5.65
article

Bowel tracking for MR-guided radiotherapy: simultaneous optimization of small bowel imaging and tracking

Astrid L.H.M.W. van Lier, Cornel Zachiu, Bas W. Raaymakers, Saskia L.C. Damen
article en
3 citations

Abstract

<i>Objective</i>. The small bowel is one of the most radiosensitive organs-at-risk during radiotherapy in the pelvis. This is further complicated due to anatomical and physiological motion. Thus, its accurate tracking becomes of particular importance during therapy delivery, to obtain better dose-toxicity relations and/or to perform safe adaptive treatments. The aim of this work is to simultaneously optimize the MR imaging sequence and motion estimation solution towards improved small bowel tracking precision during radiotherapy delivery.<i>Approach</i>. An MRI sequence was optimized, to adhere to the respiratory and peristaltic motion frequencies, by assesing the performance of an image registration algorithm on data acquired on volunteers and patients. In terms of tracking, three registration algorithms, previously-employed in the scope of image-guided radiotherapy, were investigated and optimized. The optimized scan was acquired for 7.5 min, in 18 patients and for 15 min, in 10 volunteers at a 1.5 T MRL (Unity, Elekta AB). The tracking precision was evaluated and validated by means of three different quality assurance criteria: Structural Similarity Index Measure (SSIM), Inverse Consistency (IC) and Absolute Intensity Difference.<i>Main results</i>. The optimal sequence was a balanced Fast Field Echo, which acquired a 3D volume of the abdomen, with a dynamic scan time of 1.8 s. An optical flow algorithm performed best and which was able to resolve most of the motion. This was shown by mean IC values of<1 mm and a mean SSIM>0.9for the majority of the cases. A strong positive correlation (<i>p</i> <0.001) between the registration performance and visceral fat percentage was found, where a higher visceral fat percentage gave a better registration due to the better image contrast.<i>Significance</i>. A method for simultaneous optimization of imaging and tracking was presented, which derived an imaging and registration procedure for accurate small bowel tracking on the MR-Linac.

Physics in Medicine and BiologyVol. 70(7)
Utrecht University (NL), Heidelberg University (DE), University Hospital Heidelberg (DE), University Medical Center Utrecht (NL)
Good health and well-being
Openalex Percentile: Top 5%
Advanced Radiotherapy Techniques
5.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.