Evaluation of Flashover Rate on Distribution Lines Taking into Account Insulation-covered Conductor

In Japanese distribution lines, insulation-covered conductor is generally used. Flashover characteristics of an insulator with the insulation-covered conductor are different from that with a bare conductor. However, flashover characteristics of an insulator with the insulation-covered conductor have not been well studied. To improve the accuracy of a lightning outage rate calculation method of medium-voltage distribution lines, it is important to develop an accurate flashover model of an insulator with insulation-covered conductor. In this paper, first, we experimentally examine the flashover characteristic of an insulator with a insulation-covered conductor against a short-wave-tail lightning impulse voltage. Next, we propose a flashover model of the insulator taking into account the influence of the insulation-covered conductor. Finally, we evaluate the influence of the insulation-covered conductor on the flashover rate of the insulator using the proposed flashover model. As a results, we clarify that the flashover rate on distribution lines can be up to 50% lower by taking into account the influence of the insulation-covered conductor.

Authors

Institutions

Publication Details

Journal
IEEJ Transactions on Power and Energy
Published
2025-02-28
DOI
https://doi.org/10.1541/ieejpes.145.318
Citations
1
Primary Topic
Power Line Communications and Noise
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Flashover Rate on Distribution Lines Taking into Account Insulation-covered Conductor

Ryota Mori, Kazuyuki Ishimoto, Masami Mokume, Tomohiro Maeda
1 citations
IEEJ Transactions on Power and Energy
Power Line Communications and Noise
0.73
article

Evaluation of Flashover Rate on Distribution Lines Taking into Account Insulation-covered Conductor

Ryota Mori, Kazuyuki Ishimoto, Masami Mokume, Tomohiro Maeda
article en
1 citations

Abstract

In Japanese distribution lines, insulation-covered conductor is generally used. Flashover characteristics of an insulator with the insulation-covered conductor are different from that with a bare conductor. However, flashover characteristics of an insulator with the insulation-covered conductor have not been well studied. To improve the accuracy of a lightning outage rate calculation method of medium-voltage distribution lines, it is important to develop an accurate flashover model of an insulator with insulation-covered conductor. In this paper, first, we experimentally examine the flashover characteristic of an insulator with a insulation-covered conductor against a short-wave-tail lightning impulse voltage. Next, we propose a flashover model of the insulator taking into account the influence of the insulation-covered conductor. Finally, we evaluate the influence of the insulation-covered conductor on the flashover rate of the insulator using the proposed flashover model. As a results, we clarify that the flashover rate on distribution lines can be up to 50% lower by taking into account the influence of the insulation-covered conductor.

IEEJ Transactions on Power and EnergyVol. 145(3)
Innovation Research Center (US)
Openalex Percentile: Top 31%
Power Line Communications and Noise
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.