Assessing the Test-Retest Reliability of MyotonPRO for Measuring Achilles Tendon Stiffness

<b>Objectives</b>: This study evaluates the test-retest reliability and inter-rater reliability of the MyotonPRO for measuring Achilles tendon stiffness at two standardized sites over various time frames and settings. <b>Methods</b>: Eight healthy participants underwent assessments by three raters over six visits. Tendon stiffness was measured at proximal (mid-portion) and distal (insertional) regions of the Achilles tendon at various time frames (10-15 s, 10-15 min, 24 h, and 14 days apart). Measurements included participant repositioning and two activity stimuli (daily living and sport). Reliability was calculated using the intraclass correlation coefficient (ICC), its 95% confidence interval, coefficient of variation, standard error of measurement, and minimal detectable change. <b>Results</b>: Short-term reliability (10-15 min) was excellent, with an ICC of 0.956 (0.929-0.974). Between days reliability (24 h) was good, with an ICC of 0.889 (0.802-0.938). Between weeks reliability (2 weeks) was good with an ICC of 0.886 (0.811-0.931). Short-term reliability with the simulation of activity of daily living was good, with an ICC of 0.917 (0.875-0.945). Short-term reliability with the simulation of sport was good with an ICC of 0.933 (0.891-0.96). Between days reliability with the simulation of sport was good, with an ICC of 0.920 (0.859-0.955). <b>Conclusions</b>: When used in a standardized position, the MyotonPRO demonstrates reliable repeated measurements of Achilles tendon stiffness. This protocol provides a foundation for clinical research and rehabilitation by clarifying expected reliability across minutes, days, and weeks, thus aiding clinicians and researchers in monitoring tendon adaptations and making evidence-based decisions.

Authors

Institutions

Publication Details

Journal
Journal of Functional Morphology and Kinesiology
Published
2025-02-28
DOI
https://doi.org/10.3390/jfmk10010083
Citations
6
Primary Topic
Tendon Structure and Treatment
Type
article
Field-Weighted Citation Impact
10.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the Test-Retest Reliability of MyotonPRO for Measuring Achilles Tendon Stiffness

Kryštof Voleský, Javier Courel‐Ibáñez, Michal Šteffl, James J. Tufano et al.
6 citations
Journal of Functional Morphology and Kinesiology
Tendon Structure and Treatment
10.33
article

Assessing the Test-Retest Reliability of MyotonPRO for Measuring Achilles Tendon Stiffness

Kryštof Voleský, Javier Courel‐Ibáñez, Michal Šteffl, James J. Tufano, Jan Novák, Tomáš Větrovský, Michael Janek, Jakub Katolický
article en
6 citations

Abstract

<b>Objectives</b>: This study evaluates the test-retest reliability and inter-rater reliability of the MyotonPRO for measuring Achilles tendon stiffness at two standardized sites over various time frames and settings. <b>Methods</b>: Eight healthy participants underwent assessments by three raters over six visits. Tendon stiffness was measured at proximal (mid-portion) and distal (insertional) regions of the Achilles tendon at various time frames (10-15 s, 10-15 min, 24 h, and 14 days apart). Measurements included participant repositioning and two activity stimuli (daily living and sport). Reliability was calculated using the intraclass correlation coefficient (ICC), its 95% confidence interval, coefficient of variation, standard error of measurement, and minimal detectable change. <b>Results</b>: Short-term reliability (10-15 min) was excellent, with an ICC of 0.956 (0.929-0.974). Between days reliability (24 h) was good, with an ICC of 0.889 (0.802-0.938). Between weeks reliability (2 weeks) was good with an ICC of 0.886 (0.811-0.931). Short-term reliability with the simulation of activity of daily living was good, with an ICC of 0.917 (0.875-0.945). Short-term reliability with the simulation of sport was good with an ICC of 0.933 (0.891-0.96). Between days reliability with the simulation of sport was good, with an ICC of 0.920 (0.859-0.955). <b>Conclusions</b>: When used in a standardized position, the MyotonPRO demonstrates reliable repeated measurements of Achilles tendon stiffness. This protocol provides a foundation for clinical research and rehabilitation by clarifying expected reliability across minutes, days, and weeks, thus aiding clinicians and researchers in monitoring tendon adaptations and making evidence-based decisions.

Journal of Functional Morphology and KinesiologyVol. 10(1)
Universidad de Granada (ES), Charles University (CZ), University Hospital in Motol (CZ)
Openalex Percentile: Top 2%
Tendon Structure and Treatment
10.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.