Heat transfer performance and fouling analysis of clove-treated graphene nanoplatelet nanofluid in a double-pipe heat exchanger

Abstract Nanofluids have found widespread application across various systems to enhance heat transfer, albeit with the simultaneous occurrence of fouling on heat exchange surfaces. In examining the impact of particulate fouling from nanoparticles on the heat transfer behavior of heat exchangers, this study conducted an experimental exploration utilizing green functionalized clove-treated graphene nanoplatelets (CGNP) nanofluid within a double-pipe heat exchanger (DPHE). Previous studies on nanofluids as heat transfer fluid have largely ignored the impact of particulate fouling on heat transfer performance over time. Various concentrations (0.025, 0.075, and 0.1 mass%) and flow rates (8 and 12 L min −1 ) were systematically examined over an extended operational time, with distilled water (DW) employed as a reference liquid for comparison. The experimental data were compared with simulation results at five different flow rates. The findings reveal that DW exhibited the highest overall heat transfer coefficient (OHTC) among all tested fluids with an OHTC of approximately 1660 W m 2 K −1 . Conversely, deposition occurred in the CGNP nanofluid at all concentrations over an extended operational period. Specifically, the 0.025 mass% concentration demonstrated the lowest fouling resistance in the developing stage. The fouling resistance reached constant for all the tested concentrations with estimated values of 0.15–0.16 m 2 K kW −1 . Furthermore, a flow rate of 12 L min −1 was shown to reduce the fouling resistance by 50% when decreasing the flow rate to 8 L min −1 . Overall, applying CGNP nanofluid in the DPHE over a prolonged testing duration was deemed ineffective. Exploring optimized techniques to mitigate the deposition of CGNP particles on the heat exchange pipe surfaces is necessary.

Authors

Institutions

Publication Details

Journal
Journal of Thermal Analysis and Calorimetry
Published
2025-02-27
DOI
https://doi.org/10.1007/s10973-025-14002-4
Citations
2
Primary Topic
Nanofluid Flow and Heat Transfer
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat transfer performance and fouling analysis of clove-treated graphene nanoplatelet nanofluid in a double-pipe heat exchanger

Cheen Sean Oon, Manh‐Vu Tran, Sayshar Ram Nair, M. L. G. Ho et al.
2 citations
Journal of Thermal Analysis and Calorimetry
Nanofluid Flow and Heat Transfer
1.35
article

Heat transfer performance and fouling analysis of clove-treated graphene nanoplatelet nanofluid in a double-pipe heat exchanger

Cheen Sean Oon, Manh‐Vu Tran, Sayshar Ram Nair, M. L. G. Ho, Ji Jinn Foo, Yanru Wang
article en
2 citations

Abstract

Abstract Nanofluids have found widespread application across various systems to enhance heat transfer, albeit with the simultaneous occurrence of fouling on heat exchange surfaces. In examining the impact of particulate fouling from nanoparticles on the heat transfer behavior of heat exchangers, this study conducted an experimental exploration utilizing green functionalized clove-treated graphene nanoplatelets (CGNP) nanofluid within a double-pipe heat exchanger (DPHE). Previous studies on nanofluids as heat transfer fluid have largely ignored the impact of particulate fouling on heat transfer performance over time. Various concentrations (0.025, 0.075, and 0.1 mass%) and flow rates (8 and 12 L min −1 ) were systematically examined over an extended operational time, with distilled water (DW) employed as a reference liquid for comparison. The experimental data were compared with simulation results at five different flow rates. The findings reveal that DW exhibited the highest overall heat transfer coefficient (OHTC) among all tested fluids with an OHTC of approximately 1660 W m 2 K −1 . Conversely, deposition occurred in the CGNP nanofluid at all concentrations over an extended operational period. Specifically, the 0.025 mass% concentration demonstrated the lowest fouling resistance in the developing stage. The fouling resistance reached constant for all the tested concentrations with estimated values of 0.15–0.16 m 2 K kW −1 . Furthermore, a flow rate of 12 L min −1 was shown to reduce the fouling resistance by 50% when decreasing the flow rate to 8 L min −1 . Overall, applying CGNP nanofluid in the DPHE over a prolonged testing duration was deemed ineffective. Exploring optimized techniques to mitigate the deposition of CGNP particles on the heat exchange pipe surfaces is necessary.

Journal of Thermal Analysis and CalorimetryVol. 150(7)
Monash University Malaysia (MY)
Monash University, Ministry of Higher Education, Malaysia
Openalex Percentile: Top 22%
Nanofluid Flow and Heat Transfer
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.