Research on Fourier Transform Spectral Phase Correction Algorithm Based on CTKB-NCM

In Fourier Transform Spectrometers, phase errors in spectral measurement induce distortion in reconstructed spectra. Existing phase correction algorithms demonstrate insufficient precision in addressing both linear phase and instrumental phase components, resulting in limited applications for the restored spectra in the field of precision measurement. This paper proposes an algorithm called the Cross-Teager–Kaiser ψB Energy Operator–Nonlinear Calibration Model (CTKB-NCM) for phase error correction. The algorithm first uses the cross-Teager–Kaiser ψB energy operator (CTKB) method to correct linear phase errors, then applies the Nonlinear Calibration Model (NCM) to solve for the instrument phase correction parameters at each wavenumber, and finally uses the instrument phase correction parameters to correct the residual phase after the linear phase error has been corrected. The Rao algorithm is used to determine the optimal instrument phase correction parameters. Simulation experiments demonstrate that the CTKB-NCM method achieves an order-of-magnitude improvement in normalized reconstructed spectral accuracy for SO2 gas compared to the conventional Mertz method.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2025-02-28
DOI
https://doi.org/10.3390/photonics12030219
Primary Topic
Optical Systems and Laser Technology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Fourier Transform Spectral Phase Correction Algorithm Based on CTKB-NCM

Chunhui Yan, Dong Yao, Pengzhang Dai, Zimin Huo et al.
Photonics
Optical Systems and Laser Technology
article

Research on Fourier Transform Spectral Phase Correction Algorithm Based on CTKB-NCM

Chunhui Yan, Dong Yao, Pengzhang Dai, Zimin Huo, Xiong Wang
article en

Abstract

In Fourier Transform Spectrometers, phase errors in spectral measurement induce distortion in reconstructed spectra. Existing phase correction algorithms demonstrate insufficient precision in addressing both linear phase and instrumental phase components, resulting in limited applications for the restored spectra in the field of precision measurement. This paper proposes an algorithm called the Cross-Teager–Kaiser ψB Energy Operator–Nonlinear Calibration Model (CTKB-NCM) for phase error correction. The algorithm first uses the cross-Teager–Kaiser ψB energy operator (CTKB) method to correct linear phase errors, then applies the Nonlinear Calibration Model (NCM) to solve for the instrument phase correction parameters at each wavenumber, and finally uses the instrument phase correction parameters to correct the residual phase after the linear phase error has been corrected. The Rao algorithm is used to determine the optimal instrument phase correction parameters. Simulation experiments demonstrate that the CTKB-NCM method achieves an order-of-magnitude improvement in normalized reconstructed spectral accuracy for SO2 gas compared to the conventional Mertz method.

PhotonicsVol. 12(3)
Chinese Academy of Sciences (CN), Changchun Institute of Optics, Fine Mechanics and Physics (CN), University of Chinese Academy of Sciences (CN)
Chinese Academy of Sciences, Ministry of Science and Technology of the People's Republic of China
Openalex Percentile: Top 97%
Optical Systems and Laser Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.