Seismic behavior of cold-formed steel framed multi-panel and two-story shear walls

Abstract This paper presents an experimental investigation on the seismic behavior of cold-formed steel (CFS) shear wall systems. Two sets of cyclic lateral loading tests were conducted on OSB sheathed CFS shear wall specimens. The first part of the study deals with walls constructed by connecting multiple individual wall panels with different connection methods. Focus of the second part is the lateral load response of two-story shear walls with different framing details between wall panels in neighboring floors. In both parts, the behavior of wall panels was examined with combinations of one side sheathing and a coarse fastener layout, as well as double-side sheathing and a dense fastener layout. For the multi-panel shear walls, eight full-scale specimens were tested, featuring varying configurations of CFS framing and OSB sheathing. The experiments indicate that the use of different connection details between individual wall segments does not cause any appreciable difference in wall response. Significant excessive base slip was observed in longer walls with double-side sheathing due to increased shear force demand at the base, highlighting the importance of adequate fastener layout. In the investigation of two-story shear walls, eight specimens were tested. Platform and ledger framing details were explored, each with different methods of connecting wall panels between floors. The results demonstrated the influence of framing detail on the overall behavior and failure mechanisms of the shear walls. Notably, the presence of additional OSB sheathing panels between floors enhanced the load capacity and stiffness of the specimens, mitigating damage to CFS members within the connection region. Based on the experimental findings, practical recommendations were presented for multi-panel walls and interaction between wall panels and floor support system in multi-story CFS construction.

Authors

Institutions

Publication Details

Journal
Bulletin of Earthquake Engineering
Published
2025-02-28
DOI
https://doi.org/10.1007/s10518-025-02134-9
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic behavior of cold-formed steel framed multi-panel and two-story shear walls

Baris Mert Pehlivan, Cem Topkaya, Eray Baran
Bulletin of Earthquake Engineering
Structural Load-Bearing Analysis
article

Seismic behavior of cold-formed steel framed multi-panel and two-story shear walls

Baris Mert Pehlivan, Cem Topkaya, Eray Baran
article en

Abstract

Abstract This paper presents an experimental investigation on the seismic behavior of cold-formed steel (CFS) shear wall systems. Two sets of cyclic lateral loading tests were conducted on OSB sheathed CFS shear wall specimens. The first part of the study deals with walls constructed by connecting multiple individual wall panels with different connection methods. Focus of the second part is the lateral load response of two-story shear walls with different framing details between wall panels in neighboring floors. In both parts, the behavior of wall panels was examined with combinations of one side sheathing and a coarse fastener layout, as well as double-side sheathing and a dense fastener layout. For the multi-panel shear walls, eight full-scale specimens were tested, featuring varying configurations of CFS framing and OSB sheathing. The experiments indicate that the use of different connection details between individual wall segments does not cause any appreciable difference in wall response. Significant excessive base slip was observed in longer walls with double-side sheathing due to increased shear force demand at the base, highlighting the importance of adequate fastener layout. In the investigation of two-story shear walls, eight specimens were tested. Platform and ledger framing details were explored, each with different methods of connecting wall panels between floors. The results demonstrated the influence of framing detail on the overall behavior and failure mechanisms of the shear walls. Notably, the presence of additional OSB sheathing panels between floors enhanced the load capacity and stiffness of the specimens, mitigating damage to CFS members within the connection region. Based on the experimental findings, practical recommendations were presented for multi-panel walls and interaction between wall panels and floor support system in multi-story CFS construction.

Bulletin of Earthquake EngineeringVol. 23(5)
Middle East Technical University (TR)
Orta Doğu Teknik Üniversitesi, Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Openalex Percentile: Top 96%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.