Simple surface modification of poly(methyl methacrylate) microfluidic microplates for enhanced ultrasensitive multiplexed detection of infectious diseases

Novel strategies for the simultaneous and portable detection of multiple analytes are highly favorable for clinical diagnosis and healthcare. Conventional colorimetric enzyme-linked immunosorbent assay (ELISA) is a widely used laboratory technique for medical diagnostics, quality control, and research applications. However, nonspecific absorption of proteins may lead to a reduction of functional sites, resulting in high background and low sensitivity in ELISA. Herein, we report a simple method of functionalization of poly(methyl methacrylate) (PMMA) with polylysine to be used as the microfluidic microplate substrate for enhanced ELISA, enabling rapid, ultrasensitive, and multiplexed detection of infectious diseases. FTIR and fluorescence microscopy characterization confirmed high amine densities on polylysine-modified PMMA surface, resulting in high detection sensitivity of the colorimetric ELISA on the PMMA microdevice. The ultrasensitive polylysine-modified microplate can immobilize protein within 20 min and results of the assay can be viewed by the naked eye or scanned through a simple desktop scanner for quantitative analysis within 90 min. A sandwich-type immunoassay for the rapid and sensitive detection of immunoglobulin G (IgG), hepatitis B surface antigen (HBsAg), and hepatitis B core antigen (HBcAg) was demonstrated as a proof-of-concept for multiplexed detection. The limits of detection (LOD) of 200.0 pg/mL for IgG, 180.0 pg/mL for HBsAg, and 300.0 pg/mL for HBcAg were achieved, without any specialized equipment like a microplate reader. The surface-modified microchip exhibited about 10-fold higher sensitivity than traditional microplates. This surface-modified microplate has tremendous potential as a point-of-care multiplexed testing platform for many applications ranging from clinical diagnosis to environmental monitoring, particularly in resource-limited settings.

Authors

Institutions

Publication Details

Journal
Advanced Sensor and Energy Materials
Published
2025-02-28
DOI
https://doi.org/10.1016/j.asems.2025.100142
Citations
3
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
2.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simple surface modification of poly(methyl methacrylate) microfluidic microplates for enhanced ultrasensitive multiplexed detection of infectious diseases

S. Kannan, Xiujun Li, Sharma T. Sanjay
3 citations
Advanced Sensor and Energy Materials
Biosensors and Analytical Detection
2.02
article

Simple surface modification of poly(methyl methacrylate) microfluidic microplates for enhanced ultrasensitive multiplexed detection of infectious diseases

S. Kannan, Xiujun Li, Sharma T. Sanjay
article en
3 citations

Abstract

Novel strategies for the simultaneous and portable detection of multiple analytes are highly favorable for clinical diagnosis and healthcare. Conventional colorimetric enzyme-linked immunosorbent assay (ELISA) is a widely used laboratory technique for medical diagnostics, quality control, and research applications. However, nonspecific absorption of proteins may lead to a reduction of functional sites, resulting in high background and low sensitivity in ELISA. Herein, we report a simple method of functionalization of poly(methyl methacrylate) (PMMA) with polylysine to be used as the microfluidic microplate substrate for enhanced ELISA, enabling rapid, ultrasensitive, and multiplexed detection of infectious diseases. FTIR and fluorescence microscopy characterization confirmed high amine densities on polylysine-modified PMMA surface, resulting in high detection sensitivity of the colorimetric ELISA on the PMMA microdevice. The ultrasensitive polylysine-modified microplate can immobilize protein within 20 min and results of the assay can be viewed by the naked eye or scanned through a simple desktop scanner for quantitative analysis within 90 min. A sandwich-type immunoassay for the rapid and sensitive detection of immunoglobulin G (IgG), hepatitis B surface antigen (HBsAg), and hepatitis B core antigen (HBcAg) was demonstrated as a proof-of-concept for multiplexed detection. The limits of detection (LOD) of 200.0 pg/mL for IgG, 180.0 pg/mL for HBsAg, and 300.0 pg/mL for HBcAg were achieved, without any specialized equipment like a microplate reader. The surface-modified microchip exhibited about 10-fold higher sensitivity than traditional microplates. This surface-modified microplate has tremendous potential as a point-of-care multiplexed testing platform for many applications ranging from clinical diagnosis to environmental monitoring, particularly in resource-limited settings.

Advanced Sensor and Energy MaterialsVol. 4(2)
The University of Texas at El Paso (US)
Openalex Percentile: Top 15%
Biosensors and Analytical Detection
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.