Characterization of Tungsten Sputtering Processes in a Capacitively Coupled Argon Plasma

A capacitively coupled radio-frequency argon plasma, used for tungsten sputtering deposition, is characterized using Langmuir probe measurements. Druyvesteyn’s method is used to evaluate plasma parameters through the integral of the Electron Energy Distribution Function (EEDF). In the pressure range analyzed (0.6–10 Pa), the obtained distributions are not Maxwellian, which suggests some depletion of electrons with higher energies. The obtained plasma parameters are compared with those derived from the graphical method. The electron temperature obtained via the graphical method is always lower than the effective temperatures derived from EEDFs, and vice versa, the electron density is overestimated by the graphical method. Optical Emission Spectroscopy is used to monitor the atoms sputtered in the plasma process. The behavior of excited species correlates with the plasma parameters.

Authors

Institutions

Publication Details

Journal
Plasma
Published
2025-02-28
DOI
https://doi.org/10.3390/plasma8010008
Citations
2
Primary Topic
Metal and Thin Film Mechanics
Type
article
Field-Weighted Citation Impact
1.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of Tungsten Sputtering Processes in a Capacitively Coupled Argon Plasma

D. Ripamonti, E. Vassallo, Miriam Saleh, Matteo Pedroni et al.
2 citations
Plasma
Metal and Thin Film Mechanics
1.73
article

Characterization of Tungsten Sputtering Processes in a Capacitively Coupled Argon Plasma

D. Ripamonti, E. Vassallo, Miriam Saleh, Matteo Pedroni, A. Cremona
article en
2 citations

Abstract

A capacitively coupled radio-frequency argon plasma, used for tungsten sputtering deposition, is characterized using Langmuir probe measurements. Druyvesteyn’s method is used to evaluate plasma parameters through the integral of the Electron Energy Distribution Function (EEDF). In the pressure range analyzed (0.6–10 Pa), the obtained distributions are not Maxwellian, which suggests some depletion of electrons with higher energies. The obtained plasma parameters are compared with those derived from the graphical method. The electron temperature obtained via the graphical method is always lower than the effective temperatures derived from EEDFs, and vice versa, the electron density is overestimated by the graphical method. Optical Emission Spectroscopy is used to monitor the atoms sputtered in the plasma process. The behavior of excited species correlates with the plasma parameters.

PlasmaVol. 8(1)
Institute of Condensed Matter Chemistry and Technologies for Energy (IT), Institute for the Science and Technology of Plasmas (IT), National Research Council (IT)
Openalex Percentile: Top 20%
Metal and Thin Film Mechanics
1.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.