Development of a bottle-type sensor measuring two-hand movement

Daily life activities entail the coordinated movement of both hands. Although devices for evaluating the function of one hand are available, in addition, there are currently some limitations in devices for quantitatively evaluating the two-hand movement. This study aimed to develop and examine the validity of a device, called the bottle-type sensor, which can simultaneously measure two-hand movements. A bottle-type sensor was created by wrapping a newly developed high-precision flexible sensor sheet around a three-dimensional-printed cap and body part. The force component of each sensor was calculated from the load data, and the loads for each finger were summed. Thirty healthy adults participated in the study, 21 for validity and 9 for reliability. In the validity studies, the values for the body and cap part of the bottle-type sensor were correlated with the grip and pinch forces. For reliability studies, the intraclass correlation coefficient 2, 3 were calculated comparing the results after a day. Significant positive correlations with the body and cap parts of the bottle-type sensor were found for the grip and pinch forces. Reliability studies revealed that the body part of the bottle-type sensor had an ICC of >0.75. However, the cap part had an ICC of <0.75, which was insufficient. The bottle-type sensor developed in this study showed significant correlations with the grip and pinch forces, but the cap part did not yield satisfactory results in terms of reliability. In the future, the usefulness of the bottle-type sensor needs to be clarified by improving the cap part, as well as by evaluating it during two-hand movements and measuring it in patients with various diseases.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2025-02-28
DOI
https://doi.org/10.1016/j.medengphy.2025.104315
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a bottle-type sensor measuring two-hand movement

Keisuke Irie, Daiki Watanabe, Tomoki Aoyama, Sei Uemura et al.
Medical Engineering & Physics
Muscle activation and electromyography studies
article

Development of a bottle-type sensor measuring two-hand movement

Keisuke Irie, Daiki Watanabe, Tomoki Aoyama, Sei Uemura, Momoko Nagai‐Tanima, S. Kanazawa, Soshiro Kashima
article en

Abstract

Daily life activities entail the coordinated movement of both hands. Although devices for evaluating the function of one hand are available, in addition, there are currently some limitations in devices for quantitatively evaluating the two-hand movement. This study aimed to develop and examine the validity of a device, called the bottle-type sensor, which can simultaneously measure two-hand movements. A bottle-type sensor was created by wrapping a newly developed high-precision flexible sensor sheet around a three-dimensional-printed cap and body part. The force component of each sensor was calculated from the load data, and the loads for each finger were summed. Thirty healthy adults participated in the study, 21 for validity and 9 for reliability. In the validity studies, the values for the body and cap part of the bottle-type sensor were correlated with the grip and pinch forces. For reliability studies, the intraclass correlation coefficient 2, 3 were calculated comparing the results after a day. Significant positive correlations with the body and cap parts of the bottle-type sensor were found for the grip and pinch forces. Reliability studies revealed that the body part of the bottle-type sensor had an ICC of >0.75. However, the cap part had an ICC of <0.75, which was insufficient. The bottle-type sensor developed in this study showed significant correlations with the grip and pinch forces, but the cap part did not yield satisfactory results in terms of reliability. In the future, the usefulness of the bottle-type sensor needs to be clarified by improving the cap part, as well as by evaluating it during two-hand movements and measuring it in patients with various diseases.

Medical Engineering & PhysicsVol. 138(1)
Kyoto University (JP), National Institute of Advanced Industrial Science and Technology (JP)
Ministry of Education, Culture, Sports, Science and Technology, Japan Society for the Promotion of Science
Affordable and clean energy
Openalex Percentile: Top 97%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.