An Intelligent Power Management Control Scheme for A 9 Bus Grid Tied System Powered by PV System

The internet linked society necessitates the integration of renewable energy supplies and demands in the microgrid with a power management system able to chasing, management and saving energy simultaneously. PV output varies with heat and radiation, necessitating the use of a DC/DC converter to boost PV output. Harmonics in the output are caused by static gadgets in the converter and inverter. This study presents an intelligent power management control method for grid associated system powered by PV system along with Single Ended Primary Inductance Converter (SEPIC) converter. They are executed in an IEEE 9-bus system in a zero inactivity applied state of 100% inverter based generation, where the existence of grid forming inverters is required to validate the model’s functioning also by applying the Cascaded Artificial Neural Network (ANN) controller reduces the harmonics in output. The proposed system has been verified simulations/MATLAB tests. The efficiency comparison of the (SEPIC) converter has the obtain value is 91%.

Authors

Publication Details

Published
2024-11-21
DOI
https://doi.org/10.1109/icraset63057.2024.10895150
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Intelligent Power Management Control Scheme for A 9 Bus Grid Tied System Powered by PV System

S Dhivakar., A. Johny Renoald, S Shobana, M. Vignesh
Power Systems and Renewable Energy
article

An Intelligent Power Management Control Scheme for A 9 Bus Grid Tied System Powered by PV System

S Dhivakar., A. Johny Renoald, S Shobana, M. Vignesh
article en

Abstract

The internet linked society necessitates the integration of renewable energy supplies and demands in the microgrid with a power management system able to chasing, management and saving energy simultaneously. PV output varies with heat and radiation, necessitating the use of a DC/DC converter to boost PV output. Harmonics in the output are caused by static gadgets in the converter and inverter. This study presents an intelligent power management control method for grid associated system powered by PV system along with Single Ended Primary Inductance Converter (SEPIC) converter. They are executed in an IEEE 9-bus system in a zero inactivity applied state of 100% inverter based generation, where the existence of grid forming inverters is required to validate the model’s functioning also by applying the Cascaded Artificial Neural Network (ANN) controller reduces the harmonics in output. The proposed system has been verified simulations/MATLAB tests. The efficiency comparison of the (SEPIC) converter has the obtain value is 91%.

Affordable and clean energy
Openalex Percentile: Top 68%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Intelligent Power Management Control Scheme for A 9 Bus Grid Tied System Powered by PV System — S Dhivakar., A. Johny Renoald, et al. · (2024) | TGRS Research Map | TGRS