Rhombic Shaped Photonic Crystal Biosensor for the Detection of Eye Melanoma

This paper presents the design and simulation for the detection of the eye melanoma cancer cell. The proposed design is based on the rhombic shaped structure photonic crystal. For the detection of eye melanoma cancer cells in a sample, a biosensor designed and simulated. The designed rhombic shaped photonic crystal has a hexagonal lattice and holes and a sample to detect cancer and normal cells, For the measurement of the sensor’s performance. It is constructed with silicon in air using the Finite-Difference Time-Domain tool. For the rhombic structure quality factor (Q-factor), sensitivity and full width at half maximum (FWHM) are calculated. The maximum q-factor for the rhombic structure obtained is 1873 and the sensitivity is $655(\mathrm{~nm} /$ RIU), with a resonant wavelength range of 1592 to $1593(\mathrm{~nm})$.

Authors

Publication Details

Published
2024-11-21
DOI
https://doi.org/10.1109/icraset63057.2024.10894867
Primary Topic
melanin and skin pigmentation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rhombic Shaped Photonic Crystal Biosensor for the Detection of Eye Melanoma

S. Manojkumar, P. C. Srikanth, P R Yashaswini, H S Manasa et al.
melanin and skin pigmentation
article

Rhombic Shaped Photonic Crystal Biosensor for the Detection of Eye Melanoma

S. Manojkumar, P. C. Srikanth, P R Yashaswini, H S Manasa, K V Kavana
article en

Abstract

This paper presents the design and simulation for the detection of the eye melanoma cancer cell. The proposed design is based on the rhombic shaped structure photonic crystal. For the detection of eye melanoma cancer cells in a sample, a biosensor designed and simulated. The designed rhombic shaped photonic crystal has a hexagonal lattice and holes and a sample to detect cancer and normal cells, For the measurement of the sensor’s performance. It is constructed with silicon in air using the Finite-Difference Time-Domain tool. For the rhombic structure quality factor (Q-factor), sensitivity and full width at half maximum (FWHM) are calculated. The maximum q-factor for the rhombic structure obtained is 1873 and the sensitivity is $655(\mathrm{~nm} /$ RIU), with a resonant wavelength range of 1592 to $1593(\mathrm{~nm})$.

Openalex Percentile: Top 73%
melanin and skin pigmentation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.