Effect of Gamma Radiation on TaO<i>ₓ</i> ECRAM

Electrochemical random access memory (ECRAM) is an emerging three-terminal nonvolatile memory (NVM) with highly controllable channel conductance which is promising for use as an analog memory (or synapse) in analog in-memory computing (IMC) systems. Energy-efficient analog IMC computing is particularly desirable for power-constrained, high-radiation environments such as satellites. However, little is known about the suitability of ECRAM for use in a total ionizing dose (TID) environment. This work investigates the effect of Co-60 gamma radiation on the channel conductance and noise—two properties critical for analog IMC systems—of a TaOx-based ECRAM up to 17.3 Mrad(SiO2) for both low- and high-channel-conductance state devices. A transient increase in conductance is observed in response to radiation which consists of two elements: an immediate increase in conductivity due to photocurrent and a secondary increase in conductivity, which has a slower rise and saturation and can persist for hours after exposure. This secondary, persistent photoconductivity is attributed to charging caused by hole trapping. These transient effects would not likely occur in a space environment due to the low dose rate compared with this experiment. No permanent change is found in the low conductance state (LCS) following exposure and the minor shift in the high conductance change would be less significant than the regular retention decay in this state. A permanent increase in the random telegraph noise is observed, possibly due to increased traps created in the channel. This work demonstrates that TaOx-based ECRAM is suitable for use in spaceborne analog IMC systems that are subject to significant TID.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Nuclear Science
Published
2025-02-28
DOI
https://doi.org/10.1109/tns.2025.3546663
Primary Topic
Advanced Surface Polishing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Gamma Radiation on TaOₓ ECRAM

Sapan Agarwal, David Russell Hughart, T. Patrick Xiao, A. Alec Talin et al.
IEEE Transactions on Nuclear Science
Advanced Surface Polishing Techniques
article

Effect of Gamma Radiation on TaOₓ ECRAM

Sapan Agarwal, David Russell Hughart, T. Patrick Xiao, A. Alec Talin, Matthew Spear, Matthew Marinella, Brian Zutter, Sangheon Oh, Hossain Mansur Resalat Faruque, Hugh Barnaby, Christopher H. Bennett, Max Siath, Yiyang Li, Jereme Neuendank, Andrew J. Jalbert
article en

Abstract

Electrochemical random access memory (ECRAM) is an emerging three-terminal nonvolatile memory (NVM) with highly controllable channel conductance which is promising for use as an analog memory (or synapse) in analog in-memory computing (IMC) systems. Energy-efficient analog IMC computing is particularly desirable for power-constrained, high-radiation environments such as satellites. However, little is known about the suitability of ECRAM for use in a total ionizing dose (TID) environment. This work investigates the effect of Co-60 gamma radiation on the channel conductance and noise—two properties critical for analog IMC systems—of a TaOx-based ECRAM up to 17.3 Mrad(SiO2) for both low- and high-channel-conductance state devices. A transient increase in conductance is observed in response to radiation which consists of two elements: an immediate increase in conductivity due to photocurrent and a secondary increase in conductivity, which has a slower rise and saturation and can persist for hours after exposure. This secondary, persistent photoconductivity is attributed to charging caused by hole trapping. These transient effects would not likely occur in a space environment due to the low dose rate compared with this experiment. No permanent change is found in the low conductance state (LCS) following exposure and the minor shift in the high conductance change would be less significant than the regular retention decay in this state. A permanent increase in the random telegraph noise is observed, possibly due to increased traps created in the channel. This work demonstrates that TaOx-based ECRAM is suitable for use in spaceborne analog IMC systems that are subject to significant TID.

IEEE Transactions on Nuclear ScienceVol. 72(4)
Sandia National Laboratories California (US), University of Michigan (US), Sandia National Laboratories (US), Arizona State University (US)
Openalex Percentile: Top 97%
Advanced Surface Polishing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.