Alternating pneumatic measurement: a highly usability, safe and affordable option, a case report

A simple, safe and affordable pneumothorax tamponade method was designed and tested for preliminary operation in patients requiring endotracheal intubation. Correct execution of pneumothorax tamponade with objective measurements prevents complications such as pneumonia. The method was a case study of a patient requiring endotracheal intubation. Devices such as an aneroid manometer and other materials were used to make up the measuring equipment for the design and preliminary function test. The pneumothorax tamponade device was found to be practical, safe and affordable in its preliminary assessment. It is concluded that, based on its preliminary effect, it is a practical, safe and affordable device that requires replication in practice and careful handling.

Authors

Institutions

Publication Details

Journal
Seminars in Medical Writing and Education
Published
2024-12-30
DOI
https://doi.org/10.56294/mw2024561
Primary Topic
Nosocomial Infections in ICU
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Alternating pneumatic measurement: a highly usability, safe and affordable option, a case report

Milton Carlos Guevara-Valtier, Dionicio Palacios Ríos, Ricardo Emilio Bueno Gómez, Diana Karina Torres Ruvalcaba et al.
Seminars in Medical Writing and Education
Nosocomial Infections in ICU
article

Alternating pneumatic measurement: a highly usability, safe and affordable option, a case report

Milton Carlos Guevara-Valtier, Dionicio Palacios Ríos, Ricardo Emilio Bueno Gómez, Diana Karina Torres Ruvalcaba, Norma Guadalupe Lopez Cabrera
article en

Abstract

A simple, safe and affordable pneumothorax tamponade method was designed and tested for preliminary operation in patients requiring endotracheal intubation. Correct execution of pneumothorax tamponade with objective measurements prevents complications such as pneumonia. The method was a case study of a patient requiring endotracheal intubation. Devices such as an aneroid manometer and other materials were used to make up the measuring equipment for the design and preliminary function test. The pneumothorax tamponade device was found to be practical, safe and affordable in its preliminary assessment. It is concluded that, based on its preliminary effect, it is a practical, safe and affordable device that requires replication in practice and careful handling.

Seminars in Medical Writing and EducationVol. 3
Universidad Autónoma de Nuevo León (MX), Hospital Universitario Dr José Eleuterio Gonzalez (MX)
Openalex Percentile: Top 67%
Nosocomial Infections in ICU
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.