Aristotle wires for cannulating target vessels in paediatric neuro-interventional procedures: A case-control study

BackgroundPaediatric neuro-interventional (PNI) procedures are markedly different to adult procedures and are more likely to be complicated by vasospasm. Traversing the complex tortuous anatomy in these fragile vessels requires both torque control and distal tip softness of the microwire. The Aristotle wires (Scientia Vascular Inc) are a new family of wires with design features offering both torque control and distal tip softness. We sought to assess the ability of these wires to achieve successful target vessel cannulation in paediatric patients.MethodsThe study design was a single-centre case-control study. We compared a case cohort of PNI procedures performed using the Aristotle wires (2023-24) with a control cohort using other wires (2022-23). The primary study outcome was successful cannulation of the target vessel (Yes/No) with a microcatheter.ResultsThe Aristotle wires cohort consisted of 44 targeted vessels across 40 procedures in 20 patients (F = 8; mean age 6.9, SD 6.53 years). The other wires cohort consisted of 41 targeted vessels across 41 procedures in 19 patients (F = 6; mean age 4.3, SD 4.98 years). Successful cannulation of the target vessel was achieved in 43 of 44 target vessels (97.7%) in the Aristotle wires cohort and 34 of 41 target vessels (82.9%) in the other wires cohort (<i>p</i> = .020). The rate of wire-related complications was significantly lower in the Aristotle wires cohort (0 of 44 vs 6 of 41 target vessels, <i>p</i> = .008).ConclusionAristotle wires were associated with significantly better target vessel cannulation and lower wire-related complications than other wires in PNI procedures.

Authors

Institutions

Publication Details

Journal
The Neuroradiology Journal
Published
2025-02-27
DOI
https://doi.org/10.1177/19714009251324302
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aristotle wires for cannulating target vessels in paediatric neuro-interventional procedures: A case-control study

Kartik Bhatia, Blake F. Giarola, Vinicius Carraro do Nascimento, Mark Dexter et al.
The Neuroradiology Journal
Central Venous Catheters and Hemodialysis
article

Aristotle wires for cannulating target vessels in paediatric neuro-interventional procedures: A case-control study

Kartik Bhatia, Blake F. Giarola, Vinicius Carraro do Nascimento, Mark Dexter, YJ Kim, G. Olsson, T Blane, J Vedamuthu
article en

Abstract

BackgroundPaediatric neuro-interventional (PNI) procedures are markedly different to adult procedures and are more likely to be complicated by vasospasm. Traversing the complex tortuous anatomy in these fragile vessels requires both torque control and distal tip softness of the microwire. The Aristotle wires (Scientia Vascular Inc) are a new family of wires with design features offering both torque control and distal tip softness. We sought to assess the ability of these wires to achieve successful target vessel cannulation in paediatric patients.MethodsThe study design was a single-centre case-control study. We compared a case cohort of PNI procedures performed using the Aristotle wires (2023-24) with a control cohort using other wires (2022-23). The primary study outcome was successful cannulation of the target vessel (Yes/No) with a microcatheter.ResultsThe Aristotle wires cohort consisted of 44 targeted vessels across 40 procedures in 20 patients (F = 8; mean age 6.9, SD 6.53 years). The other wires cohort consisted of 41 targeted vessels across 41 procedures in 19 patients (F = 6; mean age 4.3, SD 4.98 years). Successful cannulation of the target vessel was achieved in 43 of 44 target vessels (97.7%) in the Aristotle wires cohort and 34 of 41 target vessels (82.9%) in the other wires cohort (<i>p</i> = .020). The rate of wire-related complications was significantly lower in the Aristotle wires cohort (0 of 44 vs 6 of 41 target vessels, <i>p</i> = .008).ConclusionAristotle wires were associated with significantly better target vessel cannulation and lower wire-related complications than other wires in PNI procedures.

The Neuroradiology JournalVol. 38(6)
The University of Sydney (AU), Children's Hospital at Westmead (AU), Sydney Children’s Hospitals Network (AU)
Life below water
Openalex Percentile: Top 94%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.