About compliance with the real conditions of adopted forensic models of the victim’s fall from standing position on the back
The article considers adopted forensic models of the victim's fall from standing position on the back and their adequacy to the real conditions. A frame-by-frame analysis of 250 video recordings of cases of victims' falls from standing position on the back - both spontaneous and with a preliminary given acceleration was performed. It has been noted that the most commonly used today forensic models do not correspond to the real dynamics of the fall.
Authors
- Igor A. Tolmachev (ORCID: https://orcid.org/0000-0002-5893-520X)
- E.M. Kildyushov (ORCID: https://orcid.org/0000-0001-7571-0312)
- E.V. Tumanov (ORCID: https://orcid.org/0000-0002-8413-4895)
- S.V. Karlov (ORCID: https://orcid.org/0009-0002-1511-5719)
Institutions
- S. M. Kirov Military Medical Academy (RU)
- Pirogov Russian National Research Medical University (RU)
Publication Details
- Journal
- Forensic Medical Expertise
- Published
- 2025-02-28
- DOI
- https://doi.org/10.17116/sudmed20256801150
- Primary Topic
- Automotive and Human Injury Biomechanics
- Type
- article
- Field-Weighted Citation Impact
- 0.00