Hybrid Fixation Technique for Femoral Stem Revision in B3 Periprosthetic Fractures: A Report of Two Cases
Periprosthetic femoral fractures (PPFs) are challenging complications following total hip arthroplasty, especially in cases with compromised bone stock. We present 2 cases of Vancouver Type B3 PPF treated with a monoblock cementless long-stem prosthesis, using cement only for distal fixation. This technique provided initial stability, allowing early mobilization and eventual fracture healing with bony ingrowth. Radiographic follow-up demonstrated successful outcomes with no significant complications. Our results support the potential of this method for treating complex PPF cases, offering a solution for patients with inadequate bone quality where standard cementless fixation may be insufficient.
Authors
- Shahram Shokraneh
- Seyed Mohammad Javad Mortazavi (ORCID: https://orcid.org/0000-0003-4189-7777)
- Mohammad Ghorbanzadeh (ORCID: https://orcid.org/0000-0002-3259-4697)
- Sina Esmaeili (ORCID: https://orcid.org/0000-0002-5335-3235)
- Moein Akbari Javar
Institutions
- Imam Khomeini Hospital (IR)
- Tehran University of Medical Sciences (IR)
Publication Details
- Journal
- Arthroplasty Today
- Published
- 2025-02-28
- DOI
- https://doi.org/10.1016/j.artd.2025.101645
- Citations
- 1
- Primary Topic
- Orthopaedic implants and arthroplasty
- Type
- article
- Field-Weighted Citation Impact
- 2.01