Two-Year Data on the Efficacy and Safety of the MINIject Supraciliary Implant in Patients with Medically Uncontrolled Primary Open-Angle Glaucoma

<b>Background/Objectives</b>: The aim of this study is to evaluate the long-term efficacy and safety of the MINIject supraciliary device in patients with medically uncontrolled primary open-angle glaucoma (POAG) with up to 2 years of follow-up. <b>Methods</b>: A retrospective study was conducted using electronic medical records. Patients with medically uncontrolled POAG were included. Patients were either phakic, receiving combined phacoemulsification and MINIject, or pseudophakic receiving standalone MINIject. They were followed up for 24 months postoperatively. The primary outcomes were intraocular pressure (IOP) and use of IOP-lowering medications at 24 months postoperatively. Other secondary outcomes included IOP and use of glaucoma medications at 6, 12, and 18 months, success defined as 6 ≤ IOP ≤ 18 mmHg without the use of medications (complete) or regardless of the use of medications (qualified), average change in visual field (VF) mean deviation (MD) from baseline to 24 months, and adverse events. <b>Results</b>: The study included 37 eyes of 37 consecutive glaucoma patients. Of these, 27 underwent combined phacoemulsification with MINIject implantation and 10 had standalone MINIject. The mean preoperative IOP was 17.95 ± 4.75 mmHg on 2.16 ± 1.12 glaucoma drops. At 24 months, the mean IOP was 14.58 ± 4.55 on 0.69 ± 0.98 medications (<i>p</i> = 0.002). No difference in IOP was noted between the combined and the standalone group, although the latter had a trend for more glaucoma drops. The qualified success and the complete success rates were 67.6% and 56.8%, respectively. Average VF mean deviation progression was 0.19 ± 1.19 dB. No sight threatening complications occurred. <b>Conclusions</b>: MINIject can be a safe and effective alternative to current glaucoma devices, offering significant reduction in IOP and medication use with a good safety profile. Longer term data are needed to confirm its prolonged safety.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-02-28
DOI
https://doi.org/10.3390/jcm14051639
Citations
1
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
1.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-Year Data on the Efficacy and Safety of the MINIject Supraciliary Implant in Patients with Medically Uncontrolled Primary Open-Angle Glaucoma

Nikolaos Dervenis, Panagiotis Dervenis, Gerassimos Lascaratos, Chrysostomos Dimitriou
1 citations
Journal of Clinical Medicine
Glaucoma and retinal disorders
1.71
article

Two-Year Data on the Efficacy and Safety of the MINIject Supraciliary Implant in Patients with Medically Uncontrolled Primary Open-Angle Glaucoma

Nikolaos Dervenis, Panagiotis Dervenis, Gerassimos Lascaratos, Chrysostomos Dimitriou
article en
1 citations

Abstract

<b>Background/Objectives</b>: The aim of this study is to evaluate the long-term efficacy and safety of the MINIject supraciliary device in patients with medically uncontrolled primary open-angle glaucoma (POAG) with up to 2 years of follow-up. <b>Methods</b>: A retrospective study was conducted using electronic medical records. Patients with medically uncontrolled POAG were included. Patients were either phakic, receiving combined phacoemulsification and MINIject, or pseudophakic receiving standalone MINIject. They were followed up for 24 months postoperatively. The primary outcomes were intraocular pressure (IOP) and use of IOP-lowering medications at 24 months postoperatively. Other secondary outcomes included IOP and use of glaucoma medications at 6, 12, and 18 months, success defined as 6 ≤ IOP ≤ 18 mmHg without the use of medications (complete) or regardless of the use of medications (qualified), average change in visual field (VF) mean deviation (MD) from baseline to 24 months, and adverse events. <b>Results</b>: The study included 37 eyes of 37 consecutive glaucoma patients. Of these, 27 underwent combined phacoemulsification with MINIject implantation and 10 had standalone MINIject. The mean preoperative IOP was 17.95 ± 4.75 mmHg on 2.16 ± 1.12 glaucoma drops. At 24 months, the mean IOP was 14.58 ± 4.55 on 0.69 ± 0.98 medications (<i>p</i> = 0.002). No difference in IOP was noted between the combined and the standalone group, although the latter had a trend for more glaucoma drops. The qualified success and the complete success rates were 67.6% and 56.8%, respectively. Average VF mean deviation progression was 0.19 ± 1.19 dB. No sight threatening complications occurred. <b>Conclusions</b>: MINIject can be a safe and effective alternative to current glaucoma devices, offering significant reduction in IOP and medication use with a good safety profile. Longer term data are needed to confirm its prolonged safety.

Journal of Clinical MedicineVol. 14(5)
Moorfields Eye Hospital NHS Foundation Trust (GB), University of Liverpool (GB), King's College London (GB), East Suffolk and North Essex NHS Foundation Trust (GB)
Good health and well-being
Openalex Percentile: Top 22%
Glaucoma and retinal disorders
1.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.