The Impact of the Mass Analyzer and Tissue Section Thickness on Spatial <i>N</i>-Glycomics with MALDI-MSI

We compared matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) spatial <i>N</i>-glycomics data sets from Fourier-transform ion cyclotron resonance (FTICR) and orthogonal accelerated time-of-flight (timsTOF) mass spectrometers of FFPE preserved human kidney samples. We also tested different tissue section thicknesses. In these analyses, we assessed the impact of the mass analyzer and tissue section thickness on <i>N</i>-glycan coverage, sensitivity, and histological alignment. Our results indicate negligible differences in <i>N</i>-glycan coverage between the two mass analyzers, where <i>N</i>-glycan annotation numbers remained consistent and were highly reproducible. The timsTOF-MS analyses demonstrated significant advantages with higher duty cycles and better lateral resolution, allowing for finer spatial resolution without compromising signal integrity. Specifically, timsTOF was able to generate detailed MALDI-MS images at 20 μm step size, accurately identifying <i>N</i>-glycan Hex:5 HexNAc:5 dHex:1 as a tubular-specific marker without observable delocalization. Despite minor annotation discrepancies, where only three species detected by FTICR were not detected by using timsTOF, and a few false-positive annotations from the timsTOF analysis attributed to lower mass resolving power, the overall consistency between the instruments was high. Importantly, tissue section thickness did not affect analysis sensitivity in the timsTOF analyses, with the average glycan signal intensity remaining stable between 7 and 2 μm sections. These findings demonstrate that 2 μm thick tissue slices can be effectively used in spatial <i>N</i>-glycomics workflows, maintaining sensitivity while enhancing confidence in pathohistological evaluations.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2025-02-28
DOI
https://doi.org/10.1021/jasms.4c00494
Citations
3
Primary Topic
Glycosylation and Glycoproteins Research
Type
article
Field-Weighted Citation Impact
2.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of the Mass Analyzer and Tissue Section Thickness on Spatial N-Glycomics with MALDI-MSI

Christopher Lund O'Connor, Dušan Veličković, Marija Veličković, Markus Bitzer et al.
3 citations
Journal of the American Society for Mass Spectrometry
Glycosylation and Glycoproteins Research
2.42
article

The Impact of the Mass Analyzer and Tissue Section Thickness on Spatial N-Glycomics with MALDI-MSI

Christopher Lund O'Connor, Dušan Veličković, Marija Veličković, Markus Bitzer, Christopher Anderton
article en
3 citations

Abstract

We compared matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) spatial <i>N</i>-glycomics data sets from Fourier-transform ion cyclotron resonance (FTICR) and orthogonal accelerated time-of-flight (timsTOF) mass spectrometers of FFPE preserved human kidney samples. We also tested different tissue section thicknesses. In these analyses, we assessed the impact of the mass analyzer and tissue section thickness on <i>N</i>-glycan coverage, sensitivity, and histological alignment. Our results indicate negligible differences in <i>N</i>-glycan coverage between the two mass analyzers, where <i>N</i>-glycan annotation numbers remained consistent and were highly reproducible. The timsTOF-MS analyses demonstrated significant advantages with higher duty cycles and better lateral resolution, allowing for finer spatial resolution without compromising signal integrity. Specifically, timsTOF was able to generate detailed MALDI-MS images at 20 μm step size, accurately identifying <i>N</i>-glycan Hex:5 HexNAc:5 dHex:1 as a tubular-specific marker without observable delocalization. Despite minor annotation discrepancies, where only three species detected by FTICR were not detected by using timsTOF, and a few false-positive annotations from the timsTOF analysis attributed to lower mass resolving power, the overall consistency between the instruments was high. Importantly, tissue section thickness did not affect analysis sensitivity in the timsTOF analyses, with the average glycan signal intensity remaining stable between 7 and 2 μm sections. These findings demonstrate that 2 μm thick tissue slices can be effectively used in spatial <i>N</i>-glycomics workflows, maintaining sensitivity while enhancing confidence in pathohistological evaluations.

Journal of the American Society for Mass SpectrometryVol. 36(4)
Pacific Northwest National Laboratory (US), University of Michigan (US), Environmental Molecular Sciences Laboratory (US)
Environmental Molecular Sciences Laboratory, National Institute of Diabetes and Digestive and Kidney Diseases
Zero hunger
Openalex Percentile: Top 13%
Glycosylation and Glycoproteins Research
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.