Resonant Frequency Tracking of a Cantilever-Enhanced Fiber-Optic Photoacoustic Gas Sensor Based on Solid Absorption

The cantilever-enhanced fiber-optic photoacoustic (PA) sensor (FOPAS) has the advantages of intrinsic safety, small size, and high sensitivity. However, the resonance frequency of the FOPAS is easily affected by temperature, which leads to gas concentration measurement errors. Herein, the cantilever-enhanced FOPAS with resonance frequency tracking is presented to improve the stability of gas detection. A gold-plated silicon wafer reflects the excitation light to double-enhance the second harmonic (2<i>f</i>) PA signal resulting from gas absorption. The excited light is incident on the PA cell wall, and the solid absorption generates the first harmonic (1<i>f</i>) PA signal. Both the 1<i>f</i> and 2<i>f</i> PA signals were detected by a silicon cantilever fiber-optic spectrophone. The 1<i>f</i> PA signal obtained through frequency scanning is used for real-time tracking the resonance frequency of the cantilever. Moreover, the ambient temperature can also be obtained by the tracked resonance frequency. The experiment showed that the minimum detection limit of C<sub>2</sub>H<sub>2</sub> reached 27 ppb. The resonant frequency track can be obtained through a fast scan in just 5 s. Moreover, the standard deviation of the multiple tracking results is 1.9 Hz. When the temperature increases from 30 to 70 °C, the gas concentration detection error can be reduced from 28 to 4% by resonant frequency tracking and temperature compensation.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-02-28
DOI
https://doi.org/10.1021/acs.analchem.5c00092
Citations
12
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
9.08

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resonant Frequency Tracking of a Cantilever-Enhanced Fiber-Optic Photoacoustic Gas Sensor Based on Solid Absorption

Yufu Xu, Min Guo, Chun Sun, Wei Peng et al.
12 citations
Analytical Chemistry
Spectroscopy and Laser Applications
9.08
article

Resonant Frequency Tracking of a Cantilever-Enhanced Fiber-Optic Photoacoustic Gas Sensor Based on Solid Absorption

Yufu Xu, Min Guo, Chun Sun, Wei Peng, Chenxi Li, Ke Chen, Xinyu Zhao, Hongbin Teng
article en
12 citations

Abstract

The cantilever-enhanced fiber-optic photoacoustic (PA) sensor (FOPAS) has the advantages of intrinsic safety, small size, and high sensitivity. However, the resonance frequency of the FOPAS is easily affected by temperature, which leads to gas concentration measurement errors. Herein, the cantilever-enhanced FOPAS with resonance frequency tracking is presented to improve the stability of gas detection. A gold-plated silicon wafer reflects the excitation light to double-enhance the second harmonic (2<i>f</i>) PA signal resulting from gas absorption. The excited light is incident on the PA cell wall, and the solid absorption generates the first harmonic (1<i>f</i>) PA signal. Both the 1<i>f</i> and 2<i>f</i> PA signals were detected by a silicon cantilever fiber-optic spectrophone. The 1<i>f</i> PA signal obtained through frequency scanning is used for real-time tracking the resonance frequency of the cantilever. Moreover, the ambient temperature can also be obtained by the tracked resonance frequency. The experiment showed that the minimum detection limit of C<sub>2</sub>H<sub>2</sub> reached 27 ppb. The resonant frequency track can be obtained through a fast scan in just 5 s. Moreover, the standard deviation of the multiple tracking results is 1.9 Hz. When the temperature increases from 30 to 70 °C, the gas concentration detection error can be reduced from 28 to 4% by resonant frequency tracking and temperature compensation.

Analytical ChemistryVol. 97(9)
Shaoxing University (CN), Dalian University of Technology (CN), Dalian University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Liaoning Province, Fundamental Research Funds for the Central Universities
Affordable and clean energy
Openalex Percentile: Top 2%
Spectroscopy and Laser Applications
9.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.