Angular resolution and scanning density estimation based on a 3D to 2D Lissajous transition

Angular resolution and scanning density are important factors affecting the quality of Lissajous images. In this work, the transition characteristics from 3D to 2D Lissajous scanning curves and the relationship between 3D Lissajous scanning rotation and phase change were studied. The concept of the characteristic phase difference between 2D and 3D Lissajous scanning trajectories is introduced, and an extension method for multidimensional Lissajous scanning characteristic phase difference is established. On this basis, three key rules for the characteristic trajectories of 3D Lissajous scanning are defined. Additionally, the special patterns and phenomena of 2D Lissajous scanning from the perspective of 3D Lissajous scanning are explored, such as the occurrence of the "non-closed endpoints". On this basis, the quadrant patterns of 2D Lissajous scanning with the "non-closed endpoints" are derived. A method for calculating the scanning density for the number of 3D Lissajous scanning intersection points was proposed. Then, the double-junction circle calculation method for the angular resolution of the center region is deduced. The characteristics of the curves were analyzed for specific frequency ratios (9:7, 13:10, and 17:13). Finally, the scanning density and properties of 3D Lissajous scanning trajectories were experimentally verified. The results indicate trajectory densities of 110, 234, and 412 for frequency ratios 9:7, 13:10, and 17:13. The angular resolution under computed a frequency ratio of 17:13 was <i>ar </i>= 0,0089. The angular resolution was calculated with a computational error of <i>E </i>= 0.0001 and an accuracy of <i>ε</i>≤0.009, enabling high-resolution and high-density Lissajous scanning.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-02-28
DOI
https://doi.org/10.1364/oe.550164
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Angular resolution and scanning density estimation based on a 3D to 2D Lissajous transition

Yuanlin Xia, Xiang Guo, Zhuqing Wang, Jiaxing Tan et al.
Optics Express
Optical measurement and interference techniques
article

Angular resolution and scanning density estimation based on a 3D to 2D Lissajous transition

Yuanlin Xia, Xiang Guo, Zhuqing Wang, Jiaxing Tan, Xi Chen, Lin Zhang, Qiang Shen, Xia Cao, Shiping Jiang, Dehui Wang
article en

Abstract

Angular resolution and scanning density are important factors affecting the quality of Lissajous images. In this work, the transition characteristics from 3D to 2D Lissajous scanning curves and the relationship between 3D Lissajous scanning rotation and phase change were studied. The concept of the characteristic phase difference between 2D and 3D Lissajous scanning trajectories is introduced, and an extension method for multidimensional Lissajous scanning characteristic phase difference is established. On this basis, three key rules for the characteristic trajectories of 3D Lissajous scanning are defined. Additionally, the special patterns and phenomena of 2D Lissajous scanning from the perspective of 3D Lissajous scanning are explored, such as the occurrence of the "non-closed endpoints". On this basis, the quadrant patterns of 2D Lissajous scanning with the "non-closed endpoints" are derived. A method for calculating the scanning density for the number of 3D Lissajous scanning intersection points was proposed. Then, the double-junction circle calculation method for the angular resolution of the center region is deduced. The characteristics of the curves were analyzed for specific frequency ratios (9:7, 13:10, and 17:13). Finally, the scanning density and properties of 3D Lissajous scanning trajectories were experimentally verified. The results indicate trajectory densities of 110, 234, and 412 for frequency ratios 9:7, 13:10, and 17:13. The angular resolution under computed a frequency ratio of 17:13 was <i>ar </i>= 0,0089. The angular resolution was calculated with a computational error of <i>E </i>= 0.0001 and an accuracy of <i>ε</i>≤0.009, enabling high-resolution and high-density Lissajous scanning.

Optics ExpressVol. 33(6)
Sichuan University (CN), West China Hospital of Sichuan University (CN), Geely (China) (CN)
Natural Science Foundation of Sichuan Province, National Key Research and Development Program of China
Climate action
Openalex Percentile: Top 98%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.