Quantitative assessment of the effect of overhead and underground feeder configurations on the reliability of urban mixed distribution systems

• Impact of the ratio and location of overhead and underground feeder sections on the mixed distribution systems (MDS) reliability is evaluated. • Impact of various MDS on the customer-wise, feeder-wise, and system reliability indices is evaluated. • Reliability of various MDS are compared with those using traditional all-overhead (AO) and all-underground (AU) systems. • Impact of failure rates and repair times on EENS and ECOST due to various feeder configurations is assessed. Mixed distribution systems (MDS) aim to balance between the failure frequency and restoration time of all-overhead (AO) and all-underground (AU) distribution systems. The reliability indices of MDS are influenced by the feeder configurations of overhead lines (OHL) and underground cables (UGC), connected customer types along with the failure rates and repair times associated with OHL and UGC. This study investigates how variations in the location, ratio, failure rates and repair times of overhead and underground feeder sections within mixed feeders affect the reliability of MDS in urban environments. The reliability indices of MDS are compared with those that use AO and AU networks. In addition to looking at how the ratio and location of OHL and UGC affect reliability, four cases are analyzed to assess the effect of the variation of OHL and UGC failure rates and repair times on reliability indices for different MDS feeder configurations. Results indicate that MDS could effectively balance the reliability of the AO and AU systems, providing useful information for power system designers and policymakers for efficient utility planning and infrastructure development. Furthermore, the cost-benefit impact of OHL and UGC failure rates and repair times may differ significantly depending on the MDS feeder configurations.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-03-01
DOI
https://doi.org/10.1016/j.rineng.2025.104528
Primary Topic
Power System Reliability and Maintenance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative assessment of the effect of overhead and underground feeder configurations on the reliability of urban mixed distribution systems

A. S. Nazmul Huda, Rastko Živanović
1 links
Results in Engineering
Power System Reliability and Maintenance
article

Quantitative assessment of the effect of overhead and underground feeder configurations on the reliability of urban mixed distribution systems

A. S. Nazmul Huda, Rastko Živanović
article en

Abstract

• Impact of the ratio and location of overhead and underground feeder sections on the mixed distribution systems (MDS) reliability is evaluated. • Impact of various MDS on the customer-wise, feeder-wise, and system reliability indices is evaluated. • Reliability of various MDS are compared with those using traditional all-overhead (AO) and all-underground (AU) systems. • Impact of failure rates and repair times on EENS and ECOST due to various feeder configurations is assessed. Mixed distribution systems (MDS) aim to balance between the failure frequency and restoration time of all-overhead (AO) and all-underground (AU) distribution systems. The reliability indices of MDS are influenced by the feeder configurations of overhead lines (OHL) and underground cables (UGC), connected customer types along with the failure rates and repair times associated with OHL and UGC. This study investigates how variations in the location, ratio, failure rates and repair times of overhead and underground feeder sections within mixed feeders affect the reliability of MDS in urban environments. The reliability indices of MDS are compared with those that use AO and AU networks. In addition to looking at how the ratio and location of OHL and UGC affect reliability, four cases are analyzed to assess the effect of the variation of OHL and UGC failure rates and repair times on reliability indices for different MDS feeder configurations. Results indicate that MDS could effectively balance the reliability of the AO and AU systems, providing useful information for power system designers and policymakers for efficient utility planning and infrastructure development. Furthermore, the cost-benefit impact of OHL and UGC failure rates and repair times may differ significantly depending on the MDS feeder configurations.

Results in EngineeringVol. 25
University of Applied Sciences Upper Austria (AT), BRAC University (BD)
Sustainable cities and communities
Openalex Percentile: Top 96%
Power System Reliability and Maintenance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.