VALIDITY AND RELIABILITY OF TWO STRAIN GAUGES TO MEASURE UPPER-BODY RELATIVE STRENGTH IN GYMNASTICS STILL RINGS

The still rings routine has evolved over the last century, emphasizing increasing strength. What is paramount is not absolute but relative strength, as each gymnast hangs from the still rings and must overcome the effect of gravity on their body using their own upper limb characteristics: strength and dimension. While the vertical force produced by the gymnast is easily measured on a force plate, a specific computation is required when the force is measured in the cable, as the cables are not perfectly vertical. No publication has yet investigated the impact of cable length or the distance between the rings (i.e., the gymnast's arm span) on the tension measured in the cable. The purpose of this study is to validate strain gauges in comparison with a force plate and to provide recommendations for their use in assessing a gymnast's relative strength. To address this, a static loading procedure was performed with weights ranging from 50 to 80 kg, increasing in increments of 10 kg (50, 60, 70, 80 kg). Different distances between the still rings were tested, ranging from 50 cm (vertical cables – 0.0° angle) to 170 cm (31.1° angle), with increments of 20 cm (i.e., 10 cm on each side). Each weight was first placed on a pair of force plates (K-Deltas, Kinvent Biomécanique) before being hung in the middle of the rings with cables equipped with 1-axis strain gauges (K-Pull traction dynamometers, Kinvent Biomécanique). The largest discrepancy between the two methods was 10.31 N, which could be attributed to the sensor as well as the distance between the rings. This article provides a clear answer to the questions regarding the effects of the angle and the length of the cable on tension. Strain gauges are a smaller, lighter, and more affordable alternative to force plates while remaining reliable, valid, and discriminative, provided that the cable angle is known.

Authors

Institutions

Publication Details

Journal
Science of Gymnastics Journal
Published
2025-02-28
DOI
https://doi.org/10.52165/sgj.17.1.139-151
Citations
1
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
1.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

VALIDITY AND RELIABILITY OF TWO STRAIN GAUGES TO MEASURE UPPER-BODY RELATIVE STRENGTH IN GYMNASTICS STILL RINGS

Arnaud Gouelle, Luís Mochizuki, Tom Lecocq, Nicolas Tordi
1 citations
Science of Gymnastics Journal
Sports Performance and Training
1.72
article

VALIDITY AND RELIABILITY OF TWO STRAIN GAUGES TO MEASURE UPPER-BODY RELATIVE STRENGTH IN GYMNASTICS STILL RINGS

Arnaud Gouelle, Luís Mochizuki, Tom Lecocq, Nicolas Tordi
article en
1 citations

Abstract

The still rings routine has evolved over the last century, emphasizing increasing strength. What is paramount is not absolute but relative strength, as each gymnast hangs from the still rings and must overcome the effect of gravity on their body using their own upper limb characteristics: strength and dimension. While the vertical force produced by the gymnast is easily measured on a force plate, a specific computation is required when the force is measured in the cable, as the cables are not perfectly vertical. No publication has yet investigated the impact of cable length or the distance between the rings (i.e., the gymnast's arm span) on the tension measured in the cable. The purpose of this study is to validate strain gauges in comparison with a force plate and to provide recommendations for their use in assessing a gymnast's relative strength. To address this, a static loading procedure was performed with weights ranging from 50 to 80 kg, increasing in increments of 10 kg (50, 60, 70, 80 kg). Different distances between the still rings were tested, ranging from 50 cm (vertical cables – 0.0° angle) to 170 cm (31.1° angle), with increments of 20 cm (i.e., 10 cm on each side). Each weight was first placed on a pair of force plates (K-Deltas, Kinvent Biomécanique) before being hung in the middle of the rings with cables equipped with 1-axis strain gauges (K-Pull traction dynamometers, Kinvent Biomécanique). The largest discrepancy between the two methods was 10.31 N, which could be attributed to the sensor as well as the distance between the rings. This article provides a clear answer to the questions regarding the effects of the angle and the length of the cable on tension. Strain gauges are a smaller, lighter, and more affordable alternative to force plates while remaining reliable, valid, and discriminative, provided that the cable angle is known.

Science of Gymnastics JournalVol. 17(1)
Expro (United Kingdom) (GB), Universidade de São Paulo (BR), Fédération française de cardiologie (FR), Centre de Recherche Médecine, Sciences, Santé, Santé Mentale, Société (FR)
Openalex Percentile: Top 22%
Sports Performance and Training
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.