Diagnostic Accuracy of Pleural Fluid Cholesterol Levels in Differentiating Between Exudative and Transudative Pleural Effusions

Objective: To determine the utility of pleural fluid cholesterol levels in differentiating between exudative and transudative pleural effusions. Study Design: Cross-sectional analytical study. Place and Duration of Study: Department of Pulmonology, Combined Military Hospital, Peshawar Pakistan, from Sep to Dec 2021. Methodology: All patients aged less than 18 years, with pleural effusion confirmed on chest ultrasound, were included in our study. Patients with International Normalized Ratio >1.5, patients who were already under treatment for pleural effusion, patients on diuretics for more than 48 hours and patients not willing to participate in the study, were excluded. Light’s Criteria was used to label effusions as either exudates or transudates. Pleural fluid cholesterol ≥1.2mmol/L was considered as exudate. Results: Our study included a total of 78 patients, aged 52±21.27 years. Majority 63(80.7%) were males and most 51(65.4%) patients had exudative pleural effusion, while 27(34.6%) had transudative pleural effusion, as per Light’s Criteria. Out of 51 patients with exudative pleural effusion by Light’s Criteria, 41 had exudative pleural effusion on the basis of fluid cholesterol levels where mean pleural fluid cholesterol levels were 2.0±0.93 mmol/L and 1.04±2.32 mmol/L in exudative and transudative pleural effusions, respectively (p=0.01). Pleural fluid cholesterol levels of more than 1.2mmol/L had a diagnostic accuracy of 82%, sensitivity of 80% and specificity of 93% while the Positive Predictive Value was 95% and the Negative Predictive Value was 71%. Conclusion: Pleural fluid cholesterol levels of more than 1.2mmol/L can reliably differentiate between exudative and transudative pleural effusions.

Authors

Institutions

Publication Details

Journal
Pakistan Armed Forces Medical Journal
Published
2025-02-28
DOI
https://doi.org/10.51253/pafmj.v75i1.8066
Primary Topic
Pericarditis and Cardiac Tamponade
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Accuracy of Pleural Fluid Cholesterol Levels in Differentiating Between Exudative and Transudative Pleural Effusions

Abdul Rehman Arshad, Najmush Shakireen, Zia ul Arifeen, Muhammad Amir et al.
Pakistan Armed Forces Medical Journal
Pericarditis and Cardiac Tamponade
article

Diagnostic Accuracy of Pleural Fluid Cholesterol Levels in Differentiating Between Exudative and Transudative Pleural Effusions

Abdul Rehman Arshad, Najmush Shakireen, Zia ul Arifeen, Muhammad Amir, Javeria Wazir, Sadia Gul
article en

Abstract

Objective: To determine the utility of pleural fluid cholesterol levels in differentiating between exudative and transudative pleural effusions. Study Design: Cross-sectional analytical study. Place and Duration of Study: Department of Pulmonology, Combined Military Hospital, Peshawar Pakistan, from Sep to Dec 2021. Methodology: All patients aged less than 18 years, with pleural effusion confirmed on chest ultrasound, were included in our study. Patients with International Normalized Ratio >1.5, patients who were already under treatment for pleural effusion, patients on diuretics for more than 48 hours and patients not willing to participate in the study, were excluded. Light’s Criteria was used to label effusions as either exudates or transudates. Pleural fluid cholesterol ≥1.2mmol/L was considered as exudate. Results: Our study included a total of 78 patients, aged 52±21.27 years. Majority 63(80.7%) were males and most 51(65.4%) patients had exudative pleural effusion, while 27(34.6%) had transudative pleural effusion, as per Light’s Criteria. Out of 51 patients with exudative pleural effusion by Light’s Criteria, 41 had exudative pleural effusion on the basis of fluid cholesterol levels where mean pleural fluid cholesterol levels were 2.0±0.93 mmol/L and 1.04±2.32 mmol/L in exudative and transudative pleural effusions, respectively (p=0.01). Pleural fluid cholesterol levels of more than 1.2mmol/L had a diagnostic accuracy of 82%, sensitivity of 80% and specificity of 93% while the Positive Predictive Value was 95% and the Negative Predictive Value was 71%. Conclusion: Pleural fluid cholesterol levels of more than 1.2mmol/L can reliably differentiate between exudative and transudative pleural effusions.

Pakistan Armed Forces Medical JournalVol. 75(1)
Combined Military Hospital (PK), National University of Medical Sciences (PK), University of Engineering and Technology Peshawar (PK)
Openalex Percentile: Top 94%
Pericarditis and Cardiac Tamponade
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.