Simple and Convenient Three‐Electrode Layout for Real‐Time Electrorotation Measurement Upon Chemical Stimulation

We developed a novel electrorotation (ROT) device featuring a microwell array with three electrodes. This device allows to monitor the increase in membrane capacitance of cells subjected to chemical stimulation. The microwell array is integrated into the bottom of a fluidic channel and holds rotating cells during stimulation with a solution containing a chemical agent. Positive dielectrophoresis (p-DEP) effectively traps cells in microwells, whereas negative DEP (n-DEP) facilitates the rapid formation of single-cell presence. Alternating current (AC) voltages with a 120° phase shift applied across the three electrodes enable vertical and simultaneous rotation of cells. We observed a peak in rotation rate as a function of applied frequency, with the frequency spectrum shifting to lower frequencies as membrane capacitance increased. A positive correlation was identified between rotation rate and membrane capacitance, so monitoring in the low-frequency range is advantageous. Although n-DEP at lower frequencies risks removing cells from microwells, the continuous monitoring of the ROT rate during chemical stimulation was achieved by regulating the height of the ROT center of cells. We demonstrated the monitoring of membrane capacitance increase induced by Ca<sup>2+</sup> influx from ionomycin. This simple configuration facilitates statistical analysis of ROT rates without fluorescent labeling, making it suitable for label-free assessments of white blood cells' responses to stimuli.

Authors

Institutions

Publication Details

Journal
Electrophoresis
Published
2025-02-26
DOI
https://doi.org/10.1002/elps.8121
Citations
1
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simple and Convenient Three‐Electrode Layout for Real‐Time Electrorotation Measurement Upon Chemical Stimulation

Tomoyuki Yasukawa, Yushi Isozaki, Ryoga Yamada, Masato Suzuki et al.
1 citations
Electrophoresis
Electrical and Bioimpedance Tomography
0.73
article

Simple and Convenient Three‐Electrode Layout for Real‐Time Electrorotation Measurement Upon Chemical Stimulation

Tomoyuki Yasukawa, Yushi Isozaki, Ryoga Yamada, Masato Suzuki, Yuki Imou
article en
1 citations

Abstract

We developed a novel electrorotation (ROT) device featuring a microwell array with three electrodes. This device allows to monitor the increase in membrane capacitance of cells subjected to chemical stimulation. The microwell array is integrated into the bottom of a fluidic channel and holds rotating cells during stimulation with a solution containing a chemical agent. Positive dielectrophoresis (p-DEP) effectively traps cells in microwells, whereas negative DEP (n-DEP) facilitates the rapid formation of single-cell presence. Alternating current (AC) voltages with a 120° phase shift applied across the three electrodes enable vertical and simultaneous rotation of cells. We observed a peak in rotation rate as a function of applied frequency, with the frequency spectrum shifting to lower frequencies as membrane capacitance increased. A positive correlation was identified between rotation rate and membrane capacitance, so monitoring in the low-frequency range is advantageous. Although n-DEP at lower frequencies risks removing cells from microwells, the continuous monitoring of the ROT rate during chemical stimulation was achieved by regulating the height of the ROT center of cells. We demonstrated the monitoring of membrane capacitance increase induced by Ca<sup>2+</sup> influx from ionomycin. This simple configuration facilitates statistical analysis of ROT rates without fluorescent labeling, making it suitable for label-free assessments of white blood cells' responses to stimuli.

ElectrophoresisVol. 46(16)
University of Hyogo (JP)
New Energy and Industrial Technology Development Organization, Japan Society for the Promotion of Science
Openalex Percentile: Top 31%
Electrical and Bioimpedance Tomography
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.