Global sensitivity analysis of distance protection performance for submarine transmission systems

The distance protection performance depends on the accurate definition of the relay settings. These are computed from the line impedance, which needs, for its calculation, various parameters (such as geometry and cross-section of the cable, soil properties); their uncertainty might jeopardize the performance of the fault location algorithm. Via global sensitivity analysis, this paper investigates which are the main drivers of the distance protection performance in a submarine transmission system. The results underscore the need to better characterize the earth resistivity (via direct or indirect measurement), and the risk of the common practice to adopt “default” values for it. Also, the cable model of the EMT software tools used to compute the line impedance can be, already perse, an error source for distance protection algorithms.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-02-01
DOI
https://doi.org/10.1049/icp.2024.4694
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Global sensitivity analysis of distance protection performance for submarine transmission systems

Antonello Monti, Muhammad Muzaffar Ali Khan Khattak, Mirko Ginocchi, Ferdinanda Ponci et al.
IET conference proceedings.
Power Systems Fault Detection
article

Global sensitivity analysis of distance protection performance for submarine transmission systems

Antonello Monti, Muhammad Muzaffar Ali Khan Khattak, Mirko Ginocchi, Ferdinanda Ponci, Thanakorn Penthong, Alexander Och
article en

Abstract

The distance protection performance depends on the accurate definition of the relay settings. These are computed from the line impedance, which needs, for its calculation, various parameters (such as geometry and cross-section of the cable, soil properties); their uncertainty might jeopardize the performance of the fault location algorithm. Via global sensitivity analysis, this paper investigates which are the main drivers of the distance protection performance in a submarine transmission system. The results underscore the need to better characterize the earth resistivity (via direct or indirect measurement), and the risk of the common practice to adopt “default” values for it. Also, the cable model of the EMT software tools used to compute the line impedance can be, already perse, an error source for distance protection algorithms.

IET conference proceedings.Vol. 2024(29)
Fraunhofer Institute for Applied Information Technology (DE), RWTH Aachen University (DE)
Openalex Percentile: Top 96%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.