Comparison of Performance of Harmonic Filters Using PQ Theory

Harmonic currents produced by nonlinear loads, such as Variable Frequency Drives (VFDs), lead to voltage distortion due to voltage losses in the electrical distribution network. This voltage distortion effect, which correlates with the system impedance, negatively impacts the system's overall performance. It is crucial to assess the harmonic characteristics of the connected load to predict distorted voltage levels at the Point of Common Coupling (PCC). The grid system's harmonics are examined by simulating the grid in MATLAB, followed by FFT analysis to identify the harmonics present within the system. The shunt active power filter (SAPF) is a widely recognized solution for harmonic mitigation. However, while the SAPF lowers grid impedance, it can also lead to higher harmonic current distortion. To reduce total harmonic distortion, a hybrid filter comprising a series active power filter and a passive filter, grounded in the generalized theory of instantaneous power in three-phase circuits—commonly referred to as P-Q theory—is implemented in the system.

Authors

Institutions

Publication Details

Published
2024-12-12
DOI
https://doi.org/10.1109/icercs63125.2024.10895247
Primary Topic
Advanced Adaptive Filtering Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Performance of Harmonic Filters Using PQ Theory

Smrithi Vijayan, A. Amudha
Advanced Adaptive Filtering Techniques
article

Comparison of Performance of Harmonic Filters Using PQ Theory

Smrithi Vijayan, A. Amudha
article en

Abstract

Harmonic currents produced by nonlinear loads, such as Variable Frequency Drives (VFDs), lead to voltage distortion due to voltage losses in the electrical distribution network. This voltage distortion effect, which correlates with the system impedance, negatively impacts the system's overall performance. It is crucial to assess the harmonic characteristics of the connected load to predict distorted voltage levels at the Point of Common Coupling (PCC). The grid system's harmonics are examined by simulating the grid in MATLAB, followed by FFT analysis to identify the harmonics present within the system. The shunt active power filter (SAPF) is a widely recognized solution for harmonic mitigation. However, while the SAPF lowers grid impedance, it can also lead to higher harmonic current distortion. To reduce total harmonic distortion, a hybrid filter comprising a series active power filter and a passive filter, grounded in the generalized theory of instantaneous power in three-phase circuits—commonly referred to as P-Q theory—is implemented in the system.

Karpagam Academy of Higher Education (IN)
Affordable and clean energy
Openalex Percentile: Top 71%
Advanced Adaptive Filtering Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.