Laser Micromechanical Sensor for Measurement of the Mass of Bacterial Cell Colonies

We presented results of applying an adaptive interferometry technique, based on dynamic holograms recorded in photorefractive crystal, to accurately determine the mass of biofilm bacteria colonies by the measuring of microcantilever frequency shift. During the experimental testing, biofilms of Escherichia coli were grown on the surface of a cantilever previously coated with a BaF2 film. The proposed experimental setup is completely non-contact due to using an optical method of excitation and detection of cantilever oscillations. Based on the measured shift in the resonant frequency, the mass of the biofilm grown on the cantilever was calculated to be (2.072 ± 0.003) × 10–9 gram.

Authors

Institutions

Publication Details

Journal
Bulletin of the Russian Academy of Sciences Physics
Published
2024-12-01
DOI
https://doi.org/10.1134/s1062873824709759
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laser Micromechanical Sensor for Measurement of the Mass of Bacterial Cell Colonies

D. V. Storozhenko, Roman V. Romashko, T. A. Efimov, Konstantin N. Galkin et al.
3 links
Bulletin of the Russian Academy of Sciences Physics
Mechanical and Optical Resonators
article

Laser Micromechanical Sensor for Measurement of the Mass of Bacterial Cell Colonies

D. V. Storozhenko, Roman V. Romashko, T. A. Efimov, Konstantin N. Galkin, Anton Degtyarenko, Igor M. Chernev, Yury Shkryl, M. N. Bezruk
article en

Abstract

We presented results of applying an adaptive interferometry technique, based on dynamic holograms recorded in photorefractive crystal, to accurately determine the mass of biofilm bacteria colonies by the measuring of microcantilever frequency shift. During the experimental testing, biofilms of Escherichia coli were grown on the surface of a cantilever previously coated with a BaF2 film. The proposed experimental setup is completely non-contact due to using an optical method of excitation and detection of cantilever oscillations. Based on the measured shift in the resonant frequency, the mass of the biofilm grown on the cantilever was calculated to be (2.072 ± 0.003) × 10–9 gram.

Bulletin of the Russian Academy of Sciences PhysicsVol. 88(S3)
Russian Academy of Sciences (RU), Institute of Automation and Control Processes (RU), Federal Scientific Center of the East Asia Terrestrial Biodiversity FEB RAS (RU)
Openalex Percentile: Top 76%
Mechanical and Optical Resonators
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.