Long-Term Evaluation of Central and Peripheral Lens Densities Post Implantation of Implantable Collamer Lens V4c
The density of the anterior subcapsule increased over time after ICL implantation. Preoperative refraction and pupil size were correlated with changes in anterior subcapsule density. The central anterior subcapsule density was higher than that at the periphery, and the peripheral density of the long axis was higher than that of the short axis.
Authors
- Yinjie Jiang
- Yadi Lei
- Mingrui Cheng
- Ning Rui
- Zhiquan Mao (ORCID: https://orcid.org/0000-0001-6498-1299)
- Xiaoying Wang (ORCID: https://orcid.org/0000-0001-5419-6318)
- Mingwei Li (ORCID: https://orcid.org/0000-0001-5851-6091)
- Xun Chen (ORCID: https://orcid.org/0000-0001-6871-2758)
- I-Chun Lin (ORCID: https://orcid.org/0000-0001-6775-8914)
- Boliang Li (ORCID: https://orcid.org/0000-0003-1370-4579)
- Guanghan Xu
Institutions
- Shanghai Medical College of Fudan University (CN)
- Fudan University (CN)
- National Health and Family Planning Commission (CN)
- Eye & ENT Hospital of Fudan University (CN)
Publication Details
- Journal
- Clinical ophthalmology
- Published
- 2025-02-01
- DOI
- https://doi.org/10.2147/opth.s500512
- Citations
- 1
- Primary Topic
- Ophthalmology and Visual Impairment Studies
- Type
- article
- Field-Weighted Citation Impact
- 1.35
Funders
- National Natural Science Foundation of China