Long-Term Evaluation of Central and Peripheral Lens Densities Post Implantation of Implantable Collamer Lens V4c

The density of the anterior subcapsule increased over time after ICL implantation. Preoperative refraction and pupil size were correlated with changes in anterior subcapsule density. The central anterior subcapsule density was higher than that at the periphery, and the peripheral density of the long axis was higher than that of the short axis.

Authors

Institutions

Publication Details

Journal
Clinical ophthalmology
Published
2025-02-01
DOI
https://doi.org/10.2147/opth.s500512
Citations
1
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-Term Evaluation of Central and Peripheral Lens Densities Post Implantation of Implantable Collamer Lens V4c

Yinjie Jiang, Yadi Lei, Mingrui Cheng, Ning Rui et al.
1 citations
Clinical ophthalmology
Ophthalmology and Visual Impairment Studies
1.35
article

Long-Term Evaluation of Central and Peripheral Lens Densities Post Implantation of Implantable Collamer Lens V4c

Yinjie Jiang, Yadi Lei, Mingrui Cheng, Ning Rui, Zhiquan Mao, Xiaoying Wang, Mingwei Li, Xun Chen, I-Chun Lin, Boliang Li, Guanghan Xu
article en
1 citations

Abstract

The density of the anterior subcapsule increased over time after ICL implantation. Preoperative refraction and pupil size were correlated with changes in anterior subcapsule density. The central anterior subcapsule density was higher than that at the periphery, and the peripheral density of the long axis was higher than that of the short axis.

Clinical ophthalmologyVol. Volume 19
Shanghai Medical College of Fudan University (CN), Fudan University (CN), National Health and Family Planning Commission (CN), Eye & ENT Hospital of Fudan University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 23%
Ophthalmology and Visual Impairment Studies
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Long-Term Evaluation of Central and Peripheral Lens Densities Post Implantation of Implantable Collamer Lens V4c — Yinjie Jiang, Yadi Lei, et al. · Clinical ophthalmology (2025) | TGRS Research Map | TGRS