Analytical Method Development and Validation of Nitazoxanide by RP-HPLC Method in API and Tablet Dosage Forms

A Simple, precise and accurate RP-HPLC method was developed for determination of of Nitazoxanide in API and tablet dosage forms. The chromatographic separation was done on Cosmosil C18 Column (250mm x 4.6mm,5µm) using mobile phase MEOH+ 0.05% (OPA with TEA) Water (70+30% v/v) at flow rate 0.7ml/min and wavelength detection 340nm.The retention time for Nitazoxanide was found to be 4.333 min. Linearity was observed in the range10-50μg/ml (y=55.38x-37.01 and R² = 0.9976). The LOD and LOQ was found to be 0.4258 and 1.289 respectively. The Precision as indicated by repeatability study was having %RSD less than 2. The accuracy, intraday and interday were also found to be less than 2. Hence the proposed method is successfully developed and validated.

Authors

Institutions

Publication Details

Journal
Asian Journal of Pharmaceutical Analysis
Published
2024-12-30
DOI
https://doi.org/10.52711/2231-5675.2024.00038
Citations
2
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Method Development and Validation of Nitazoxanide by RP-HPLC Method in API and Tablet Dosage Forms

Javesh Patil, Richa Kothari, Devshree Yashwantbhai Patel, Harsha Vasudev Chaudhari
2 citations
Asian Journal of Pharmaceutical Analysis
Analytical Methods in Pharmaceuticals
0.47
article

Analytical Method Development and Validation of Nitazoxanide by RP-HPLC Method in API and Tablet Dosage Forms

Javesh Patil, Richa Kothari, Devshree Yashwantbhai Patel, Harsha Vasudev Chaudhari
article en
2 citations

Abstract

A Simple, precise and accurate RP-HPLC method was developed for determination of of Nitazoxanide in API and tablet dosage forms. The chromatographic separation was done on Cosmosil C18 Column (250mm x 4.6mm,5µm) using mobile phase MEOH+ 0.05% (OPA with TEA) Water (70+30% v/v) at flow rate 0.7ml/min and wavelength detection 340nm.The retention time for Nitazoxanide was found to be 4.333 min. Linearity was observed in the range10-50μg/ml (y=55.38x-37.01 and R² = 0.9976). The LOD and LOQ was found to be 0.4258 and 1.289 respectively. The Precision as indicated by repeatability study was having %RSD less than 2. The accuracy, intraday and interday were also found to be less than 2. Hence the proposed method is successfully developed and validated.

Asian Journal of Pharmaceutical Analysis
Shri Vile Parle Kelavani Mandal (IN)
Openalex Percentile: Top 39%
Analytical Methods in Pharmaceuticals
0.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines