Comprehensive Development and Validation of a High-Performance RP-HPLC Method for the Quantitative Analysis of Levocetirizine

The abstract discusses the reverse-phase high-performance liquid chromatography (RP-HPLC) method for the determination of Levocetirizine hydrochloride (HCl) in a tablet formulation and its validation. This effectiveness in treating allergic rhinitis and chronic idiopathic urticaria, Levocetirizine HCl, for its strong affinity to H1 receptors, entails accurate methods for identification and isolation. The RP-HPLC method was fine-tuned with a retention time of 3.87, a resolution of 1.34, and a plate count of 7125 to give sharp peaks and promising chromatographic separations. Validation was done in accordance with ICH guidelines using relevant methods like specificity, linearity (high correlation coefficient of 0.99997 across a concentration range of 2.0–30.0 μg/mL), accuracy (recovery), precision (repeatability and intermediate precision), limits of detection (LOD), and limits of quantification (LOQ). Among other data calculations from analyzing really circulating tablets, which confirmed the reliability of the methodology, the percent of the inactive substance in tablets in the test was close to what was expected. High rigidity and consistency are the factors that place the methodology in empirical QA labs for pharmaceutical quality control, even though the application of the method may differ from product to product. The technique naturally requires adherence to the standards, and this is its merit for the formulation of pharmaceutical formulations. Over and above, the RP-HPLC method is a selective, accurate, and reliable way of testing Levocetirizine HCl strength. This is a basic need for the product to be really potent and safe for the human body.

Authors

Institutions

Publication Details

Journal
Asian Journal of Pharmaceutical Analysis
Published
2024-12-30
DOI
https://doi.org/10.52711/2231-5675.2024.00046
Citations
2
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.47
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comprehensive Development and Validation of a High-Performance RP-HPLC Method for the Quantitative Analysis of Levocetirizine

D Patil, Amitkumar R. Dhankani, Mansi A. Dhankani, Sunil P. Pawar et al.
2 citations
Asian Journal of Pharmaceutical Analysis
Analytical Methods in Pharmaceuticals
0.47
article

Comprehensive Development and Validation of a High-Performance RP-HPLC Method for the Quantitative Analysis of Levocetirizine

D Patil, Amitkumar R. Dhankani, Mansi A. Dhankani, Sunil P. Pawar, Devendra Mahale, Divyani Rajendra
article en
2 citations

Abstract

The abstract discusses the reverse-phase high-performance liquid chromatography (RP-HPLC) method for the determination of Levocetirizine hydrochloride (HCl) in a tablet formulation and its validation. This effectiveness in treating allergic rhinitis and chronic idiopathic urticaria, Levocetirizine HCl, for its strong affinity to H1 receptors, entails accurate methods for identification and isolation. The RP-HPLC method was fine-tuned with a retention time of 3.87, a resolution of 1.34, and a plate count of 7125 to give sharp peaks and promising chromatographic separations. Validation was done in accordance with ICH guidelines using relevant methods like specificity, linearity (high correlation coefficient of 0.99997 across a concentration range of 2.0–30.0 μg/mL), accuracy (recovery), precision (repeatability and intermediate precision), limits of detection (LOD), and limits of quantification (LOQ). Among other data calculations from analyzing really circulating tablets, which confirmed the reliability of the methodology, the percent of the inactive substance in tablets in the test was close to what was expected. High rigidity and consistency are the factors that place the methodology in empirical QA labs for pharmaceutical quality control, even though the application of the method may differ from product to product. The technique naturally requires adherence to the standards, and this is its merit for the formulation of pharmaceutical formulations. Over and above, the RP-HPLC method is a selective, accurate, and reliable way of testing Levocetirizine HCl strength. This is a basic need for the product to be really potent and safe for the human body.

Asian Journal of Pharmaceutical Analysis
Shri Vile Parle Kelavani Mandal (IN), M. P. Shah Medical College (IN)
Openalex Percentile: Top 39%
Analytical Methods in Pharmaceuticals
0.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.