Development of a new stability indicating RP-HPLC Method for the determination of Tofacitinib and to develop the Validated method

We have validated a RP HPLC method to accurately quantify Tofacitinib, a pharmaceutical compound. For separation we used a Kromosil C18 column measuring 4.8mm× 150mm with particle size of 5μm. The mobile phase consisted of a mixture of methanol and water in a ratio of 45:55% v/v. throughout the analysis the mobile phase flowed at a rate of 1.0mL/min. we. Quantified Tofacitinib using a UV detector set to monitor absorbance at 254nm. Importantly Tofacitinib retention time, in this system was determined to be 4.35 minutes ensuring efficient analysis. We thoroughly assessed the linearity of the method across concentrations ranging from 15 to 90μg/mL which revealed an exceptional correlation coefficient of 0.999. This high level of linearity demonstrates the methods suitability for quantifying Tofacitinib over a concentration range. Additionally, we achieved a recovery rate for Tofacitinib at 99.24% further validating the accuracy and precision of the method. Significantly this developed method adheres to validation standards outlined in the International Council, for Harmonization (ICH) guidelines confirming its selectivity, precision and accuracy according to prescribed criteria. As a result the suggested RP HPLC technique serves as a sturdy method to conduct regular quality control tests on Tofacitinib in pharmaceutical products. This ensures that the medication maintains a trustworthy dosage, for usage.

Authors

Institutions

Publication Details

Journal
Asian Journal of Pharmaceutical Analysis
Published
2024-12-30
DOI
https://doi.org/10.52711/2231-5675.2024.00037
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a new stability indicating RP-HPLC Method for the determination of Tofacitinib and to develop the Validated method

K. Vijayasri, C. Parthiban, M. Sudhakar, Vinay Tadi
Asian Journal of Pharmaceutical Analysis
Analytical Methods in Pharmaceuticals
article

Development of a new stability indicating RP-HPLC Method for the determination of Tofacitinib and to develop the Validated method

K. Vijayasri, C. Parthiban, M. Sudhakar, Vinay Tadi
article en

Abstract

We have validated a RP HPLC method to accurately quantify Tofacitinib, a pharmaceutical compound. For separation we used a Kromosil C18 column measuring 4.8mm× 150mm with particle size of 5μm. The mobile phase consisted of a mixture of methanol and water in a ratio of 45:55% v/v. throughout the analysis the mobile phase flowed at a rate of 1.0mL/min. we. Quantified Tofacitinib using a UV detector set to monitor absorbance at 254nm. Importantly Tofacitinib retention time, in this system was determined to be 4.35 minutes ensuring efficient analysis. We thoroughly assessed the linearity of the method across concentrations ranging from 15 to 90μg/mL which revealed an exceptional correlation coefficient of 0.999. This high level of linearity demonstrates the methods suitability for quantifying Tofacitinib over a concentration range. Additionally, we achieved a recovery rate for Tofacitinib at 99.24% further validating the accuracy and precision of the method. Significantly this developed method adheres to validation standards outlined in the International Council, for Harmonization (ICH) guidelines confirming its selectivity, precision and accuracy according to prescribed criteria. As a result the suggested RP HPLC technique serves as a sturdy method to conduct regular quality control tests on Tofacitinib in pharmaceutical products. This ensures that the medication maintains a trustworthy dosage, for usage.

Asian Journal of Pharmaceutical Analysis
G Pulla Reddy Dental College & Hospital (IN)
Openalex Percentile: Top 74%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.