Verification of the analytical performance of the serum anti-thyroperoxidase antibody assay on the Abbott Alinity ci®: Experience from the Biochemistry Laboratory of the Mohammed VI University Hospital of Oujda

The objective of this study was to evaluate the analytical performance of the measurement of anti-thyroperoxidase antibodies (anti-TPO antibodies) in human serum and plasma, using chemiluminescent microparticle immunoassay (CMIA), in accordance with Domain A criteria of the medical biology method verification/validation guide. The results of the anti-TPO antibody serum assays show good repeatability for the three levels (1: low, 2: medium, and 3: high), with respective coefficients of variation (CV) of 1.67%, 1.97%, and 1.17%. Similarly, intermediate precision is considered satisfactory, with CV of 1.90% for level 1, 1.96% for level 2, and 1.38% for level 3. Comparison with the reference CV defined by the RICOS (Reference Institute for Clinical and Healthcare Standards) confirms the reliability and compliance of the results. The results allowed us to verify the performance of the light chain Lambda assay method and compare it with the analytical objectives set in the accreditation process in which our laboratory is engaged.

Authors

Publication Details

Journal
GSC Biological and Pharmaceutical Sciences
Published
2025-02-26
DOI
https://doi.org/10.30574/gscbps.2025.30.2.0067
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Verification of the analytical performance of the serum anti-thyroperoxidase antibody assay on the Abbott Alinity ci®: Experience from the Biochemistry Laboratory of the Mohammed VI University Hospital of Oujda

Dounia El Moujtahide, El-houcine Sebbar, Karim Jamal, Mohammed Choukri et al.
GSC Biological and Pharmaceutical Sciences
Clinical Laboratory Practices and Quality Control
article

Verification of the analytical performance of the serum anti-thyroperoxidase antibody assay on the Abbott Alinity ci®: Experience from the Biochemistry Laboratory of the Mohammed VI University Hospital of Oujda

Dounia El Moujtahide, El-houcine Sebbar, Karim Jamal, Mohammed Choukri, Oumaima kharkhach, Imane Douichi, Sara Moulay Rchid
article en

Abstract

The objective of this study was to evaluate the analytical performance of the measurement of anti-thyroperoxidase antibodies (anti-TPO antibodies) in human serum and plasma, using chemiluminescent microparticle immunoassay (CMIA), in accordance with Domain A criteria of the medical biology method verification/validation guide. The results of the anti-TPO antibody serum assays show good repeatability for the three levels (1: low, 2: medium, and 3: high), with respective coefficients of variation (CV) of 1.67%, 1.97%, and 1.17%. Similarly, intermediate precision is considered satisfactory, with CV of 1.90% for level 1, 1.96% for level 2, and 1.38% for level 3. Comparison with the reference CV defined by the RICOS (Reference Institute for Clinical and Healthcare Standards) confirms the reliability and compliance of the results. The results allowed us to verify the performance of the light chain Lambda assay method and compare it with the analytical objectives set in the accreditation process in which our laboratory is engaged.

GSC Biological and Pharmaceutical SciencesVol. 30(2)
Openalex Percentile: Top 95%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.