IBC Oxford University Oral Abstract 25 - Laparoscopic delivery of a novel enterotomy capture device between self-forming magnetic anastomosis in Roux-en-Y gastric bypass (RYGB) patients for the creation of a side-side jejunal-jejunal anastomosis

Abstract Background In previously bi-partition studies, a magnetic anastomosis has demonstrated the ability to reduce anastomosis complications such as leaks and bleeding, however previous delivery methods required the creation an enterotomy with delayed anastomosis creation. We report the procedure feasibility and 30-day results of a first ever use in humans of a novel surgical technique that eliminates the need to close the enterotomies via conventional methods after creating the anastomosis and facilitates an immediate lumen opening between two new coupled self-forming magnets (SFM) in RYGB patients. Methods Prospective non-randomized single centre trial. Surgery consisted in creating an immediate communication in a side-to-side jejunal-jejunal anastomosis intraluminally through a novel temporary enterotomy control and capture (ECC) device. All devices were deployed and delivered laparoscopically. Results A total of 5 patients were recruited, with a mean age of 35.8 (27–43) years, sex-ratio (60% F) and initial BMI of 44.8 ± 7.6 kg/m2. All procedures were performed laparoscopically. There was no conversion or peri-operative mortality. All ECCs and SFMs were delivered and connected with no delivery malfunctions, completed in an anastomosis creation time of 10 minutes (enterotomy to magnet coupling). All ECC and SFMs passed with no retentions. A total of 1 procedure adverse events (AE) occurred due to poor tolerance to oral intake from gastro-jejunal anastomosis inflammation. 0 AE occurred during the 30-day follow up period. Conclusions Preliminary and procedure feasibility data of these new surgical techniques and devices suggest the procedures are both feasible and safe in RYGB surgery. Further and longer studies are warranted.

Authors

Publication Details

Journal
British journal of surgery
Published
2025-02-01
DOI
https://doi.org/10.1093/bjs/znaf036.025
Primary Topic
Bariatric Surgery and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IBC Oxford University Oral Abstract 25 - Laparoscopic delivery of a novel enterotomy capture device between self-forming magnetic anastomosis in Roux-en-Y gastric bypass (RYGB) patients for the creation of a side-side jejunal-jejunal anastomosis

Pedro Moya Marín, Javier Contreras, A Guerra, M E Mellafe et al.
British journal of surgery
Bariatric Surgery and Outcomes
article

IBC Oxford University Oral Abstract 25 - Laparoscopic delivery of a novel enterotomy capture device between self-forming magnetic anastomosis in Roux-en-Y gastric bypass (RYGB) patients for the creation of a side-side jejunal-jejunal anastomosis

Pedro Moya Marín, Javier Contreras, A Guerra, M E Mellafe, Í Darvich
article en

Abstract

Abstract Background In previously bi-partition studies, a magnetic anastomosis has demonstrated the ability to reduce anastomosis complications such as leaks and bleeding, however previous delivery methods required the creation an enterotomy with delayed anastomosis creation. We report the procedure feasibility and 30-day results of a first ever use in humans of a novel surgical technique that eliminates the need to close the enterotomies via conventional methods after creating the anastomosis and facilitates an immediate lumen opening between two new coupled self-forming magnets (SFM) in RYGB patients. Methods Prospective non-randomized single centre trial. Surgery consisted in creating an immediate communication in a side-to-side jejunal-jejunal anastomosis intraluminally through a novel temporary enterotomy control and capture (ECC) device. All devices were deployed and delivered laparoscopically. Results A total of 5 patients were recruited, with a mean age of 35.8 (27–43) years, sex-ratio (60% F) and initial BMI of 44.8 ± 7.6 kg/m2. All procedures were performed laparoscopically. There was no conversion or peri-operative mortality. All ECCs and SFMs were delivered and connected with no delivery malfunctions, completed in an anastomosis creation time of 10 minutes (enterotomy to magnet coupling). All ECC and SFMs passed with no retentions. A total of 1 procedure adverse events (AE) occurred due to poor tolerance to oral intake from gastro-jejunal anastomosis inflammation. 0 AE occurred during the 30-day follow up period. Conclusions Preliminary and procedure feasibility data of these new surgical techniques and devices suggest the procedures are both feasible and safe in RYGB surgery. Further and longer studies are warranted.

British journal of surgeryVol. 112(Supplement_5)
Openalex Percentile: Top 94%
Bariatric Surgery and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.