Acute Seizure Activity During F-18 FDG PET/CT Imaging
We report a 62-year-old man with acute seizure during FDG PET/CT imaging. Initially admitted for newly diagnosed epilepsy, CT and MRI brain studies were unremarkable. Subsequent PET/CT showed focal tracer uptake in the left hippocampus with jerking of bilateral upper limbs and trunk. Delayed PET/CT supported the initial findings of transient seizure activity. This timely diagnosis allowed for rapid optimization of his anti-epileptic agents for the rest of the admission. This case illustrates a rare presentation of seizure during FDG PET/CT scanning and highlights the importance of distinguishing between motion artifacts and genuine seizure activity for timely diagnosis and management.
Authors
- Arvind Sinha (ORCID: https://orcid.org/0000-0002-7988-7171)
- Hoi Yin Loi
- Sanjay Pillai
- Juncheng Huang (ORCID: https://orcid.org/0009-0004-1603-5088)
- Kannan Chidambaram
Institutions
- National University Hospital (SG)
- National University Health System (SG)
Publication Details
- Journal
- Clinical nuclear medicine open.
- Published
- 2025-02-26
- DOI
- https://doi.org/10.1097/nm9.0000000000000022
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00