EMT-Based RDR and DWT Protection Techniques Simulation of Three-Winding Power Transformer

Recently, as inverter-based VREs are connected to the power grid, fault phenomena different from those of conventional synchronous generator-based power grids are appearing. This paper was conducted as a preliminary step in the development of an improved protective relaying algorithm that can prevent malfunctions in transformer systems. First, we describe the RDR based on the second harmonic using FFT, and the transformer protection technique based on DWT. We model a 345/161/23kV, 600MVA three-winding power transformer system using real system data. After reviewing the accuracy of the result of the steady-state simulation, we analyze the transients of magnetizing inrush, winding ground fault, and winding short-circuit fault. Finally, we simulate and implement the RDR protection technique with second-harmonic restraint using FFT of PSCAD library in EMT tools, and the protection of power transformer using DWT of EMT library and verify its performance.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2025-02-26
DOI
https://doi.org/10.5370/kiee.2025.74.2.258
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EMT-Based RDR and DWT Protection Techniques Simulation of Three-Winding Power Transformer

Chul-Won Park, Kyungmin Lee
The Transactions of The Korean Institute of Electrical Engineers
Power Systems Fault Detection
article

EMT-Based RDR and DWT Protection Techniques Simulation of Three-Winding Power Transformer

Chul-Won Park, Kyungmin Lee
article en

Abstract

Recently, as inverter-based VREs are connected to the power grid, fault phenomena different from those of conventional synchronous generator-based power grids are appearing. This paper was conducted as a preliminary step in the development of an improved protective relaying algorithm that can prevent malfunctions in transformer systems. First, we describe the RDR based on the second harmonic using FFT, and the transformer protection technique based on DWT. We model a 345/161/23kV, 600MVA three-winding power transformer system using real system data. After reviewing the accuracy of the result of the steady-state simulation, we analyze the transients of magnetizing inrush, winding ground fault, and winding short-circuit fault. Finally, we simulate and implement the RDR protection technique with second-harmonic restraint using FFT of PSCAD library in EMT tools, and the protection of power transformer using DWT of EMT library and verify its performance.

The Transactions of The Korean Institute of Electrical EngineersVol. 74(2)
Affordable and clean energy
Openalex Percentile: Top 96%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

EMT-Based RDR and DWT Protection Techniques Simulation of Three-Winding Power Transformer — Chul-Won Park, Kyungmin Lee · The Transactions of The Korean Institute of Electrical Engineers (2025) | TGRS Research Map | TGRS