Could Microplasma Ionization and Ultrahigh Mass Resolution Alleviate Chemical Separations for Elemental and Isotopic Analysis?

At the extremes, all analytical spectrometric measurements are limited by the resolution of the spectrometer system. Spectral overlaps, isobars in the case of mass spectrometry, can lead to the implementation of complex and time-consuming chemical separations to alleviate those interferences. In the area of elemental/isotopic mass spectrometry, use of sector-field instruments can provide a mass resolution of ~10,000, but still necessitate chemical separations. Described here is the coupling of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to ultra-high resolution Orbitrap mass analyzer systems to yield mass resolution values ranging from 70k to 1M. Resolution of this order, with commensurate improvements in precision and accuracy, holds the promise to affect elemental/isotopic determinations without the need for chemical separations.

Authors

Institutions

Publication Details

Journal
CHIMIA International Journal for Chemistry
Published
2025-02-26
DOI
https://doi.org/10.2533/chimia.2025.60
Citations
2
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Could Microplasma Ionization and Ultrahigh Mass Resolution Alleviate Chemical Separations for Elemental and Isotopic Analysis?

R. Kenneth Marcus
2 citations
CHIMIA International Journal for Chemistry
Mass Spectrometry Techniques and Applications
1.51
article

Could Microplasma Ionization and Ultrahigh Mass Resolution Alleviate Chemical Separations for Elemental and Isotopic Analysis?

R. Kenneth Marcus
article en
2 citations

Abstract

At the extremes, all analytical spectrometric measurements are limited by the resolution of the spectrometer system. Spectral overlaps, isobars in the case of mass spectrometry, can lead to the implementation of complex and time-consuming chemical separations to alleviate those interferences. In the area of elemental/isotopic mass spectrometry, use of sector-field instruments can provide a mass resolution of ~10,000, but still necessitate chemical separations. Described here is the coupling of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to ultra-high resolution Orbitrap mass analyzer systems to yield mass resolution values ranging from 70k to 1M. Resolution of this order, with commensurate improvements in precision and accuracy, holds the promise to affect elemental/isotopic determinations without the need for chemical separations.

CHIMIA International Journal for ChemistryVol. 79(1-2)
Clemson University (US)
U.S. Department of Energy, National Nuclear Security Administration, Office of Defense Nuclear Nonproliferation, Oak Ridge National Laboratory, Pacific Northwest National Laboratory
Openalex Percentile: Top 21%
Mass Spectrometry Techniques and Applications
1.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.