Sinter-joining of two different bioceramic materials

In this study, we successfully created an implant to mimic natural bone by combining a load-bearing shell made of zirconia (cortical bone) with an osteoconductive filling made of hydroxyapatite (cancellous bone). Using additive manufacturing, both parts were produced separately followed by a sinter-joining process to form one hybrid final part. We first tested the sinter-joining process on a simple ring-in-ring design, creating a defined press-fit between the outer and inner ring. We also introduced sinter supports to ensure excellent alignment and manufactured biaxial bending plates to test the mechanical resistance. We found a significant increase in the maximal measured force from (72±53) N to (366±88) N for a 5 % and 10 % press-fit, respectively. Furthermore, we successfully manufactured a more complex bone implant with this sinter-joining method.

Authors

Publication Details

Journal
Open Ceramics
Published
2025-02-26
DOI
https://doi.org/10.1016/j.oceram.2025.100759
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sinter-joining of two different bioceramic materials

Jürgen Stampfl, Martin Schwentenwein, Christoph P. Hofstetter, Stefan Baudis et al.
Open Ceramics
Bone Tissue Engineering Materials
article

Sinter-joining of two different bioceramic materials

Jürgen Stampfl, Martin Schwentenwein, Christoph P. Hofstetter, Stefan Baudis, Sarah Nistler
article en

Abstract

In this study, we successfully created an implant to mimic natural bone by combining a load-bearing shell made of zirconia (cortical bone) with an osteoconductive filling made of hydroxyapatite (cancellous bone). Using additive manufacturing, both parts were produced separately followed by a sinter-joining process to form one hybrid final part. We first tested the sinter-joining process on a simple ring-in-ring design, creating a defined press-fit between the outer and inner ring. We also introduced sinter supports to ensure excellent alignment and manufactured biaxial bending plates to test the mechanical resistance. We found a significant increase in the maximal measured force from (72±53) N to (366±88) N for a 5 % and 10 % press-fit, respectively. Furthermore, we successfully manufactured a more complex bone implant with this sinter-joining method.

Open CeramicsVol. 22
Openalex Percentile: Top 97%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.