Research on Overvoltage Monitoring Technology for Distributed New Energy Intelligent Stations

Distributed renewable energy sources such as wind, solar, and small hydropower of the new distribution network are mainly connected to the grid through distribution lines, which are susceptible to lightning overvoltage. Therefore, this paper conducts a lightning risk assessment of the active distribution network system, including the photovoltaic (PV) side and the line-side. The study analyzes the effectiveness of two lightning protection measures: strengthening insulation and installing lightning arresters in the new distribution network. Strengthening insulation involves enhancing the first three towers and all line towers. However, the results show that both methods cannot effectively reduce the lightning failure rate on the PV-side and may even lead to adverse effects. Additionally, the analysis of in stalling lightning arresters reveals that installing them on the first-level towers of the distribution line can significantly reduce the impact of lightning on both the line and PV-sides. In particular, installing lightning arresters simultaneously on the first three towers closest to the PV-side can drastically reduce the overall lightning trip rate on the line-side.

Authors

Institutions

Publication Details

Journal
Distributed Generation & Alternative Energy Journal
Published
2025-02-19
DOI
https://doi.org/10.13052/dgaej2156-3306.3965
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Overvoltage Monitoring Technology for Distributed New Energy Intelligent Stations

Zhidu Huang, Yajuan Chen, Shan Li, Wei Huang et al.
Distributed Generation & Alternative Energy Journal
Smart Grid and Power Systems
article

Research on Overvoltage Monitoring Technology for Distributed New Energy Intelligent Stations

Zhidu Huang, Yajuan Chen, Shan Li, Wei Huang, Longfei Zhang
article en

Abstract

Distributed renewable energy sources such as wind, solar, and small hydropower of the new distribution network are mainly connected to the grid through distribution lines, which are susceptible to lightning overvoltage. Therefore, this paper conducts a lightning risk assessment of the active distribution network system, including the photovoltaic (PV) side and the line-side. The study analyzes the effectiveness of two lightning protection measures: strengthening insulation and installing lightning arresters in the new distribution network. Strengthening insulation involves enhancing the first three towers and all line towers. However, the results show that both methods cannot effectively reduce the lightning failure rate on the PV-side and may even lead to adverse effects. Additionally, the analysis of in stalling lightning arresters reveals that installing them on the first-level towers of the distribution line can significantly reduce the impact of lightning on both the line and PV-sides. In particular, installing lightning arresters simultaneously on the first three towers closest to the PV-side can drastically reduce the overall lightning trip rate on the line-side.

Distributed Generation & Alternative Energy Journal
Electric Power Research Institute (US), Power Grid Corporation (India) (IN)
Openalex Percentile: Top 97%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.