Evaluation of Optimum Insulation Thickness According to External Wall Types to Be Used in Buildings to Be Reconstructed in Turkey

The external walls of a building represent the interface between the interior and exterior environments. Insulating external walls represents the most cost-effective means of ensuring indoor comfort. Despite the prevailing assumption that insulation will increase the cost of the building, this study has demonstrated that this is not the case. Notwithstanding the increase in investment costs, the application of insulation to the external walls has been demonstrated to result in a reduction in fuel consumption and operating costs. In accordance with TS 825, there are five distinct degree-day zones, with the requisite heat loads in these zones exhibiting variability. Accordingly, a cost-based methodology is required to ascertain the optimal insulation thicknesses for the various degree-day zones. In this study, the gains to be obtained in the case of using three different insulation materials for five different wall types to be used in the buildings to be built instead of the buildings destroyed in the earthquake in Turkey in 2023 were analyzed. Samples from three degree-day zones affected by earthquakes were assessed for insulation, wall structures, and fuel types. The study assesses optimum insulation thickness, investment cost, annual fuel savings, annual economic benefits, and investment payback period.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-02-26
DOI
https://doi.org/10.3390/app15052497
Citations
2
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Optimum Insulation Thickness According to External Wall Types to Be Used in Buildings to Be Reconstructed in Turkey

Nil Aras, Nuri Şişman, Çisil Timuralp, Haydar Aras
2 citations
Applied Sciences
Building Energy and Comfort Optimization
2.01
article

Evaluation of Optimum Insulation Thickness According to External Wall Types to Be Used in Buildings to Be Reconstructed in Turkey

Nil Aras, Nuri Şişman, Çisil Timuralp, Haydar Aras
article en
2 citations

Abstract

The external walls of a building represent the interface between the interior and exterior environments. Insulating external walls represents the most cost-effective means of ensuring indoor comfort. Despite the prevailing assumption that insulation will increase the cost of the building, this study has demonstrated that this is not the case. Notwithstanding the increase in investment costs, the application of insulation to the external walls has been demonstrated to result in a reduction in fuel consumption and operating costs. In accordance with TS 825, there are five distinct degree-day zones, with the requisite heat loads in these zones exhibiting variability. Accordingly, a cost-based methodology is required to ascertain the optimal insulation thicknesses for the various degree-day zones. In this study, the gains to be obtained in the case of using three different insulation materials for five different wall types to be used in the buildings to be built instead of the buildings destroyed in the earthquake in Turkey in 2023 were analyzed. Samples from three degree-day zones affected by earthquakes were assessed for insulation, wall structures, and fuel types. The study assesses optimum insulation thickness, investment cost, annual fuel savings, annual economic benefits, and investment payback period.

Applied SciencesVol. 15(5)
Eskisehir Technical University (TR), Eskişehir Osmangazi University (TR)
Openalex Percentile: Top 16%
Building Energy and Comfort Optimization
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Optimum Insulation Thickness According to External Wall Types to Be Used in Buildings to Be Reconstructed in Turkey — Nil Aras, Nuri Şişman, et al. · Applied Sciences (2025) | TGRS Research Map | TGRS