Comparison of Refractive Prediction Errors of Toric Intraocular Lens Formulae

Introduction Toric intraocular lenses (IOLs) are effective in correcting astigmatism; however, with multiple IOL toric formulae available, identifying the most accurate formula is important. The IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany) provides two in-built toric IOL formulae, the Barrett TK Toric (BTT) and Haigis Toric (HT), which sometimes differ in astigmatism predictions for a particular IOL power. This study investigates the accuracy of these formulae in predicting postoperative refraction. Methods This retrospective study included 52 eyes from 52 patients undergoing uncomplicated cataract surgery with AcrySof IQ Toric IOL implantation (Alcon Laboratories Inc., Fort Worth, Texas, United States). Biometric data, including axial length, anterior chamber depth, lens thickness, and total keratometry, were measured using the IOLMaster 700. Predicted residual spherical equivalence (SE) and astigmatism were calculated using BTT and HT formulae. Postoperative refractive outcomes were assessed at least four weeks post-surgery. Differences in prediction errors in SE and astigmatism were assessed. Results The median absolute error in SE prediction was comparable between BTT and HT formulae (0.195 D vs. 0.185 D; p=1.000), with no significant difference in the proportion of eyes achieving absolute prediction errors ≤0.25 D, ≤0.50 D, ≤0.75 D, or ≤1.00 D. For astigmatism, the HT formula demonstrated lower mean absolute errors (MAE: 0.41±0.33 D) and centroid errors (0.18 D @ 70°) compared to BTT (MAE: 0.47±0.36 D; centroid error: 0.32 D @ 76°; p<0.001). Conclusion Both BTT and HT formulae exhibit similarly high accuracy in predicting postoperative SE. HT performed statistically better for astigmatism prediction; however, the difference was negligible and not clinically significant.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-02-26
DOI
https://doi.org/10.7759/cureus.79679
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Refractive Prediction Errors of Toric Intraocular Lens Formulae

Keith Ong, Michelle Bai
Cureus
Ophthalmology and Visual Impairment Studies
article

Comparison of Refractive Prediction Errors of Toric Intraocular Lens Formulae

Keith Ong, Michelle Bai
article en

Abstract

Introduction Toric intraocular lenses (IOLs) are effective in correcting astigmatism; however, with multiple IOL toric formulae available, identifying the most accurate formula is important. The IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany) provides two in-built toric IOL formulae, the Barrett TK Toric (BTT) and Haigis Toric (HT), which sometimes differ in astigmatism predictions for a particular IOL power. This study investigates the accuracy of these formulae in predicting postoperative refraction. Methods This retrospective study included 52 eyes from 52 patients undergoing uncomplicated cataract surgery with AcrySof IQ Toric IOL implantation (Alcon Laboratories Inc., Fort Worth, Texas, United States). Biometric data, including axial length, anterior chamber depth, lens thickness, and total keratometry, were measured using the IOLMaster 700. Predicted residual spherical equivalence (SE) and astigmatism were calculated using BTT and HT formulae. Postoperative refractive outcomes were assessed at least four weeks post-surgery. Differences in prediction errors in SE and astigmatism were assessed. Results The median absolute error in SE prediction was comparable between BTT and HT formulae (0.195 D vs. 0.185 D; p=1.000), with no significant difference in the proportion of eyes achieving absolute prediction errors ≤0.25 D, ≤0.50 D, ≤0.75 D, or ≤1.00 D. For astigmatism, the HT formula demonstrated lower mean absolute errors (MAE: 0.41±0.33 D) and centroid errors (0.18 D @ 70°) compared to BTT (MAE: 0.47±0.36 D; centroid error: 0.32 D @ 76°; p<0.001). Conclusion Both BTT and HT formulae exhibit similarly high accuracy in predicting postoperative SE. HT performed statistically better for astigmatism prediction; however, the difference was negligible and not clinically significant.

CureusVol. 17(2)
The University of Sydney (AU), Sutherland Hospital (AU), Sydney Adventist Hospital (AU), Royal North Shore Hospital (AU), Cairns Hospital (AU), Northern Sydney Local Health District (AU), Sydney Orthopaedic Research Institute (AU), Western Sydney University (AU)
Openalex Percentile: Top 94%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.