Design and performance of the ALPS II regeneration cavity

The regeneration cavity (RC) is a critical component of the Any Light Particle Search II (ALPS II) experiment. It increases the signal from possible axions and axion-like particles in the experiment by nearly four orders of magnitude. The total round-trip optical losses of the power circulating in the cavity must be minimized in order to maximize the resonant enhancement of the cavity, which is an important figure of merit for ALPS II. Lower optical losses also increase the cavity storage time, and with the 123 meter long ALPS II RC we have demonstrated the longest storage time of a two-mirror optical cavity. We measured a storage time of 7.17±0.01<i>m</i><i>s</i>, equivalent to a linewidth of 44.4 Hz and a finesse of 27,500 at a wavelength of 1064 nm.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-02-26
DOI
https://doi.org/10.1364/oe.540297
Citations
1
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
4.99

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and performance of the ALPS II regeneration cavity

T. Kozłowski, A. Lindner, L.‐W. Wei, Aaron Spector et al.
1 citations
Optics Express
Particle accelerators and beam dynamics
4.99
article

Design and performance of the ALPS II regeneration cavity

T. Kozłowski, A. Lindner, L.‐W. Wei, Aaron Spector, Kanioar Karan, A. Ejlli, Harold Hollis, B. Willke, Dominique Tanner, H. Grote, Ayman Hallal, Daniel C. Brotherton, Henry Fraedrich, Isabella Oceano, Guido Müller
article en
1 citations

Abstract

The regeneration cavity (RC) is a critical component of the Any Light Particle Search II (ALPS II) experiment. It increases the signal from possible axions and axion-like particles in the experiment by nearly four orders of magnitude. The total round-trip optical losses of the power circulating in the cavity must be minimized in order to maximize the resonant enhancement of the cavity, which is an important figure of merit for ALPS II. Lower optical losses also increase the cavity storage time, and with the 123 meter long ALPS II RC we have demonstrated the longest storage time of a two-mirror optical cavity. We measured a storage time of 7.17±0.01<i>m</i><i>s</i>, equivalent to a linewidth of 44.4 Hz and a finesse of 27,500 at a wavelength of 1064 nm.

Optics ExpressVol. 33(5)
Leibniz University Hannover (DE), University of Florida (US), Max Planck Institute for Gravitational Physics (DE), Cardiff University (GB)
Science and Technology Facilities Council
Sustainable cities and communities
Openalex Percentile: Top 7%
Particle accelerators and beam dynamics
4.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and performance of the ALPS II regeneration cavity — T. Kozłowski, A. Lindner, et al. · Optics Express (2025) | TGRS Research Map | TGRS