Retrofit of a combined heat and power plant with gas and steam turbines to hydrogen with special consideration of the balance of plant

In 2020, around 44% of natural gas in Germany was used in combined heat and power as well as in combined cycle gas turbines plants. As district heating will play an important role in future heating planning, the retrofit of these plants to hydrogen is a viable option. This paper analyzes a typical combined cycle power plant, including its balance of plant under consideration of different hydrogen blends. We show that retrofits are limited by the gas turbines in many cases. For instance, the preheater in the fuel gas system must be dimensioned higher than with natural gas. While pressure losses are very low, materials could be a problem due to higher volume flows. Additionally, the higher combustion temperatures in the gas turbine can compensate for possible efficiency losses in the Heat Recovery System Generator (HRSG) and steam turbine making this a suitable approach for electricity-led plants. However, for heat-led plants this leads to a reduction in the district heating output. Therefore, the performance of the HRSG must be considered as a limiting factor for heat-driven plants and the change in flue gas must be analyzed. Currently, hydrogen blends of 20–40 vol.-% appear feasible without major adjustments. The water content in the exhaust gas can also lead to problems in the HRSG and flue gas aftertreatment due to changes in the dew point. For higher hydrogen blends, a plant specific analysis is recommended. • Overview of a CHP-CCGT retrofit to hydrogen, incl. main balance of plant parts. • Retrofit analysis of a power plant model supplying a district heating network. • Analysis of Joule-Thomson effect on fuel gas system, focusing on preheater size. • Synthesis of calculations & literature on subsystems, focusing on technical aspects.

Authors

Institutions

Publication Details

Journal
International Journal of Hydrogen Energy
Published
2025-02-26
DOI
https://doi.org/10.1016/j.ijhydene.2025.02.160
Citations
2
Primary Topic
Advanced Power Generation Technologies
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retrofit of a combined heat and power plant with gas and steam turbines to hydrogen with special consideration of the balance of plant

Tanja Clees, Malte Pfennig, Barbara Schiffer
2 citations
International Journal of Hydrogen Energy
Advanced Power Generation Technologies
1.46
article

Retrofit of a combined heat and power plant with gas and steam turbines to hydrogen with special consideration of the balance of plant

Tanja Clees, Malte Pfennig, Barbara Schiffer
article en
2 citations

Abstract

In 2020, around 44% of natural gas in Germany was used in combined heat and power as well as in combined cycle gas turbines plants. As district heating will play an important role in future heating planning, the retrofit of these plants to hydrogen is a viable option. This paper analyzes a typical combined cycle power plant, including its balance of plant under consideration of different hydrogen blends. We show that retrofits are limited by the gas turbines in many cases. For instance, the preheater in the fuel gas system must be dimensioned higher than with natural gas. While pressure losses are very low, materials could be a problem due to higher volume flows. Additionally, the higher combustion temperatures in the gas turbine can compensate for possible efficiency losses in the Heat Recovery System Generator (HRSG) and steam turbine making this a suitable approach for electricity-led plants. However, for heat-led plants this leads to a reduction in the district heating output. Therefore, the performance of the HRSG must be considered as a limiting factor for heat-driven plants and the change in flue gas must be analyzed. Currently, hydrogen blends of 20–40 vol.-% appear feasible without major adjustments. The water content in the exhaust gas can also lead to problems in the HRSG and flue gas aftertreatment due to changes in the dew point. For higher hydrogen blends, a plant specific analysis is recommended. • Overview of a CHP-CCGT retrofit to hydrogen, incl. main balance of plant parts. • Retrofit analysis of a power plant model supplying a district heating network. • Analysis of Joule-Thomson effect on fuel gas system, focusing on preheater size. • Synthesis of calculations & literature on subsystems, focusing on technical aspects.

International Journal of Hydrogen EnergyVol. 144
Hochschule Bonn-Rhein-Sieg (DE), Fraunhofer Institute for Algorithms and Scientific Computing (DE)
Bundesministerium für Bildung und Forschung
Affordable and clean energy
Openalex Percentile: Top 19%
Advanced Power Generation Technologies
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.