A Micro-Nodal Tungsten-Rhenium Thin-Film Thermocouple Based on Electrohydrodynamic Printing

High-temperature thin-film thermocouples (TFTCs) have gained significant attention in the aerospace and energy industries due to their compact size and millisecond response time. Although previous studies have reduced the size of TFTCs to the millimeter scale, the heat flow field has continued to limit temperature measurement accuracy. To address this issue, this study used an electrohydrodynamic printing process to fabricate tungsten-rhenium TFTCs with a thickness at the micrometer scale. In the static test, the tungsten-rhenium TFTCs showed good performance with a measurement accuracy better than 1.2%, repeatability better than 0.99%, and a drift rate of 0.72%/h. In dynamic tests, the response time was 1.2 ms. Additionally, during flame gun heating tests, the response time and temperature measurement accuracy exceeded those of the standard thermocouple.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-02-26
DOI
https://doi.org/10.3390/ma18051031
Citations
2
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Micro-Nodal Tungsten-Rhenium Thin-Film Thermocouple Based on Electrohydrodynamic Printing

Jihao Li, Zhenyin Hai, Shigui Gong, Shi-Long Liu et al.
2 citations
Materials
Advanced Sensor Technologies Research
1.35
article

A Micro-Nodal Tungsten-Rhenium Thin-Film Thermocouple Based on Electrohydrodynamic Printing

Jihao Li, Zhenyin Hai, Shigui Gong, Shi-Long Liu, Ying Li, Jun Chen, Zhichun Liu, Shijie Hu, Shuaida Wang
article en
2 citations

Abstract

High-temperature thin-film thermocouples (TFTCs) have gained significant attention in the aerospace and energy industries due to their compact size and millisecond response time. Although previous studies have reduced the size of TFTCs to the millimeter scale, the heat flow field has continued to limit temperature measurement accuracy. To address this issue, this study used an electrohydrodynamic printing process to fabricate tungsten-rhenium TFTCs with a thickness at the micrometer scale. In the static test, the tungsten-rhenium TFTCs showed good performance with a measurement accuracy better than 1.2%, repeatability better than 0.99%, and a drift rate of 0.72%/h. In dynamic tests, the response time was 1.2 ms. Additionally, during flame gun heating tests, the response time and temperature measurement accuracy exceeded those of the standard thermocouple.

MaterialsVol. 18(5)
Shenzhen Polytechnic University (CN), Xiamen University (CN), Ocean University of China (CN), Xiamen University of Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Shandong Province
Affordable and clean energy
Openalex Percentile: Top 22%
Advanced Sensor Technologies Research
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.