Pile-up free fluorescence lifetime imaging with a SPAD-based single pixel camera

In the last years, single-pixel imaging (SPI) has been extensively utilized in fluorescence lifetime imaging (FLIM) experiments. In this context, to attain high temporal resolution, time-correlated single photon counting (TCSPC) is typically adopted, with the major drawback of the pile-up phenomenon, that limits the photon count rate to 1-5% of the laser excitation rate. This clearly hinders the possibility of monitoring a wide variety of biological phenomena in real-time. In this paper, to the best of our knowledge, we apply for the first time to a single-pixel camera (SPC) a hardware-based method, that allows to completely avoid the onset of pile-up by matching the dead time of the employed single-photon avalanche diode (SPAD) detector to an integer multiple of the laser period. We therefore demonstrate that undistorted and high-fidelity lifetime maps can be acquired at count rates (40%) well above the classic pile-up limitation, even in the presence of computational imaging algorithms. These results are supported by a thorough analysis of both the raw data prior to the reconstruction process and the final reconstructed lifetime maps.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-02-26
DOI
https://doi.org/10.1364/oe.555297
Citations
3
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
3.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pile-up free fluorescence lifetime imaging with a SPAD-based single pixel camera

Giulia Acconcia, Alberto Ghezzi, Ivan Rech, Cosimo D’Andrea et al.
3 citations
Optics Express
Advanced Optical Sensing Technologies
3.58
article

Pile-up free fluorescence lifetime imaging with a SPAD-based single pixel camera

Giulia Acconcia, Alberto Ghezzi, Ivan Rech, Cosimo D’Andrea, Andrea Farina, Ivan Labanca, Serena Farina
article en
3 citations

Abstract

In the last years, single-pixel imaging (SPI) has been extensively utilized in fluorescence lifetime imaging (FLIM) experiments. In this context, to attain high temporal resolution, time-correlated single photon counting (TCSPC) is typically adopted, with the major drawback of the pile-up phenomenon, that limits the photon count rate to 1-5% of the laser excitation rate. This clearly hinders the possibility of monitoring a wide variety of biological phenomena in real-time. In this paper, to the best of our knowledge, we apply for the first time to a single-pixel camera (SPC) a hardware-based method, that allows to completely avoid the onset of pile-up by matching the dead time of the employed single-photon avalanche diode (SPAD) detector to an integer multiple of the laser period. We therefore demonstrate that undistorted and high-fidelity lifetime maps can be acquired at count rates (40%) well above the classic pile-up limitation, even in the presence of computational imaging algorithms. These results are supported by a thorough analysis of both the raw data prior to the reconstruction process and the final reconstructed lifetime maps.

Optics ExpressVol. 33(11)
Italian Institute of Technology (IT), Istituto di Fotonica e Nanotecnologie (IT), Center for Nano Science and Technology (IT), Politecnico di Milano (IT)
European Commission, Ministero dell'Università e della Ricerca, European Research Council, H2020 Marie Skłodowska-Curie Actions
Affordable and clean energy
Openalex Percentile: Top 9%
Advanced Optical Sensing Technologies
3.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.