Laser-driven high-resolution MeV x-ray tomography

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade () with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

Authors

Institutions

Publication Details

Journal
Optica
Published
2025-02-26
DOI
https://doi.org/10.1364/optica.542536
Citations
6
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
4.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laser-driven high-resolution MeV x-ray tomography

S. Zahedpour, D. C. Gautier, Matthew J. Sheats, R. Hollinger et al.
6 citations
Optica
Advanced X-ray and CT Imaging
4.04
article

Laser-driven high-resolution MeV x-ray tomography

S. Zahedpour, D. C. Gautier, Matthew J. Sheats, R. Hollinger, Alejandro Figueroa Bengoa, G. Zeraouli, Ping Zhang, Joel Heidemann, J. J. Rocca, Shoujun Wang, Matthew Faulkner, Yong Wang, Shannon Scott, R. J. Edwards, James King
article en
6 citations

Abstract

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade () with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

OpticaVol. 12(3)
Los Alamos National Laboratory (US), SLAC National Accelerator Laboratory (US), AWE Nuclear Security Technologies (GB), Colorado State University (US)
Affordable and clean energy
Openalex Percentile: Top 7%
Advanced X-ray and CT Imaging
4.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.