Design and commission of TPC prototype integrated with 266 nm UV laser

Abstract The Time Projection Chamber (TPC) serves as the baseline main tracking detector in the Circular Electron Positron Collider Reference Design Report (CEPC refTDR) and is vital for the International Linear Collider (ILC). To achieve high position resolution and dE/dx measurements, a TPC prototype with a UV laser tracking system was developed at the Institute of High Energy Physics, CAS. The prototype includes 6 layers of horizontal single-tracks, 3 layers of vertical multi-beam lasers around the TPC detector chamber, a fast electronics readout with 1000 channels, a Gaseous Electron Multiplier (GEM) detector with an active area of 200 mm × 200 mm. This paper discusses the designs for the drift chamber, field cage, endplate readout, UV laser tracking system, and DAQ system, along with the commissioning results. The results show the reconstruction of 6 laser layers and indicate that a spatial resolution of 97.6 μm is achieved after a 50 mm drift distance in a 0 T magnetic field. All findings indicate that the TPC detector prototype with the integrated UV laser system has been successfully developed and is prepared for further research.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-02-01
DOI
https://doi.org/10.1088/1748-0221/20/02/p02025
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and commission of TPC prototype integrated with 266 nm UV laser

Z. Y. Yuan, H. R. Qi, Yuchun Chang, C. X. Yu et al.
Journal of Instrumentation
Particle Detector Development and Performance
article

Design and commission of TPC prototype integrated with 266 nm UV laser

Z. Y. Yuan, H. R. Qi, Yuchun Chang, C. X. Yu, J.C. Wang, Jiabao Zhang, Z. Y. Deng, X. She
article en

Abstract

Abstract The Time Projection Chamber (TPC) serves as the baseline main tracking detector in the Circular Electron Positron Collider Reference Design Report (CEPC refTDR) and is vital for the International Linear Collider (ILC). To achieve high position resolution and dE/dx measurements, a TPC prototype with a UV laser tracking system was developed at the Institute of High Energy Physics, CAS. The prototype includes 6 layers of horizontal single-tracks, 3 layers of vertical multi-beam lasers around the TPC detector chamber, a fast electronics readout with 1000 channels, a Gaseous Electron Multiplier (GEM) detector with an active area of 200 mm × 200 mm. This paper discusses the designs for the drift chamber, field cage, endplate readout, UV laser tracking system, and DAQ system, along with the commissioning results. The results show the reconstruction of 6 laser layers and indicate that a spatial resolution of 97.6 μm is achieved after a 50 mm drift distance in a 0 T magnetic field. All findings indicate that the TPC detector prototype with the integrated UV laser system has been successfully developed and is prepared for further research.

Journal of InstrumentationVol. 20(02)
Peking University (CN), Nankai University (CN), Institute of High Energy Physics (CN), University of Chinese Academy of Sciences (CN), Tsinghua University (CN)
Openalex Percentile: Top 98%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and commission of TPC prototype integrated with 266 nm UV laser — Z. Y. Yuan, H. R. Qi, et al. · Journal of Instrumentation (2025) | TGRS Research Map | TGRS