Corrosion characteristics of heat-treated biomedical grade 316L stainless steel in simulated body fluids

In this study, we investigated the corrosion behaviour of heat-treated biomedical grade 316L Stainless Steel (SS 316L) in simulated body fluids. SS 316L is widely used in biomedical applications due to its excellent mechanical properties and biocompatibility. Nonetheless, concerns about its susceptibility to corrosion in physiological environments persist. To mitigate these concerns, heat treatment was employed to enhance the material's corrosion resistance by modifying its microstructure. Specimens underwent heat treatment at varying temperatures (1050–1200 °C) for 1 h, followed by rapid water cooling. The corrosion behaviour of both untreated and heat-treated samples was assessed using electrochemical techniques, including potentiodynamic polarization and electrochemical impedance spectroscopy, in simulated body fluids with 0.9 % NaCl. The specimen exhibiting optimal corrosion resistance in this solution was further evaluated in Hanks Balanced Salt Solution enriched with Mg 2+ and Ca 2+ ions (HBSS + ). The results highlighted that the specimen subjected to heat treatment at 1200 °C, followed by water quenching (HT1200 °C/1hr/WQ), experienced deterioration due to galvanic effects between the γ-austenite and δ-ferrite phases. Conversely, the specimen heat-treated at 1100 °C, followed by water quenching (HT1100 °C/1hr/WQ), demonstrated the highest corrosion resistance in 0.9 % NaCl, even surpassing the untreated sample. This improved corrosion resistance was attributed to the combination of moderate and uniform grain size and complete transformation to the austenitic phase during heat treatment. However, when the (HT1100 °C/1hr/WQ) specimen was immersed in a more aggressive HBSS + solution, its corrosion resistance deteriorated, suggesting the influence of the medium despite microstructural improvement.

Authors

Institutions

Publication Details

Journal
Results in Materials
Published
2025-02-26
DOI
https://doi.org/10.1016/j.rinma.2025.100676
Citations
5
Primary Topic
Hydrogen embrittlement and corrosion behaviors in metals
Type
article
Field-Weighted Citation Impact
3.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corrosion characteristics of heat-treated biomedical grade 316L stainless steel in simulated body fluids

Babatunde Abiodun Obadele, Peter Apata Olubambi, Bukola Joseph Babalola, Ufoma Silas Anamu et al.
5 citations
Results in Materials
Hydrogen embrittlement and corrosion behaviors in metals
3.25
article

Corrosion characteristics of heat-treated biomedical grade 316L stainless steel in simulated body fluids

Babatunde Abiodun Obadele, Peter Apata Olubambi, Bukola Joseph Babalola, Ufoma Silas Anamu, Ngeleshi Michel Kibambe
article en
5 citations

Abstract

In this study, we investigated the corrosion behaviour of heat-treated biomedical grade 316L Stainless Steel (SS 316L) in simulated body fluids. SS 316L is widely used in biomedical applications due to its excellent mechanical properties and biocompatibility. Nonetheless, concerns about its susceptibility to corrosion in physiological environments persist. To mitigate these concerns, heat treatment was employed to enhance the material's corrosion resistance by modifying its microstructure. Specimens underwent heat treatment at varying temperatures (1050–1200 °C) for 1 h, followed by rapid water cooling. The corrosion behaviour of both untreated and heat-treated samples was assessed using electrochemical techniques, including potentiodynamic polarization and electrochemical impedance spectroscopy, in simulated body fluids with 0.9 % NaCl. The specimen exhibiting optimal corrosion resistance in this solution was further evaluated in Hanks Balanced Salt Solution enriched with Mg 2+ and Ca 2+ ions (HBSS + ). The results highlighted that the specimen subjected to heat treatment at 1200 °C, followed by water quenching (HT1200 °C/1hr/WQ), experienced deterioration due to galvanic effects between the γ-austenite and δ-ferrite phases. Conversely, the specimen heat-treated at 1100 °C, followed by water quenching (HT1100 °C/1hr/WQ), demonstrated the highest corrosion resistance in 0.9 % NaCl, even surpassing the untreated sample. This improved corrosion resistance was attributed to the combination of moderate and uniform grain size and complete transformation to the austenitic phase during heat treatment. However, when the (HT1100 °C/1hr/WQ) specimen was immersed in a more aggressive HBSS + solution, its corrosion resistance deteriorated, suggesting the influence of the medium despite microstructural improvement.

Results in MaterialsVol. 26
Tshwane University of Technology (ZA), Botswana International University of Science and Technology (BW), University of Johannesburg (ZA)
University of Johannesburg
Openalex Percentile: Top 9%
Hydrogen embrittlement and corrosion behaviors in metals
3.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.