Single-Use Electrochemical Aptamer-Based Sensors for Calibration-Free Measurements in Human Saliva via Dual-Frequency Approaches: Prospects and Challenges

Despite the rapid growth in aptamer-based biosensor research, there remains a significant demand for aptasensors that operate without the need for sample preparation and calibration, to better facilitate real-world applications. Electrochemical aptamer-based (EAB) sensors, particularly those utilizing a dual-frequency, calibration-free approach, have shown promising advances toward commercialization. Single-use, disposable sensors represent a cost-effective solution for at-home and on-site point-of-care (POC) diagnostics. However, the development of these sensors presents unique challenges compared to <i>in vivo</i> monitoring and reusable platforms, with pronounced variations across sensors and batches. Motivated by these challenges, we have comprehensively investigated the dual-frequency, calibration-free approach, focusing on sensor-to-sensor and batch-to-batch variations. Our research explored the use of a nonresponsive frequency-based ratiometric method for detecting cocaine with laser-ablated, disposable EAB sensors. Additionally, to overcome the absence of nonresponsive frequencies in some aptasensors, we developed strategies to modify the aptamer structure and optimize operational conditions, effectively tailoring nonresponsive frequencies to allow for rapid result turnover. Moreover, we assessed the effects of various filter types on saliva pretreatment using liquid chromatography with tandem mass spectrometry (LCMS/MS) and developed a saliva collection workflow using an oral swab. This workflow and the disposable aptasensors developed herein achieved low μM sensitivity in saliva, with results obtainable in under 5 min, including saliva collection and processing. Furthermore, our findings indicate that certain food and drink residues in saliva can compromise sensor accuracy, highlighting an area for future refinement.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-02-26
DOI
https://doi.org/10.1021/acs.analchem.4c06802
Citations
5
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
3.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-Use Electrochemical Aptamer-Based Sensors for Calibration-Free Measurements in Human Saliva via Dual-Frequency Approaches: Prospects and Challenges

Onyekachi Raymond, Yasmin Liu, Rishi Ranjan Pandey, Mary Jane McCarthy
5 citations
Analytical Chemistry
Advanced Chemical Sensor Technologies
3.37
article

Single-Use Electrochemical Aptamer-Based Sensors for Calibration-Free Measurements in Human Saliva via Dual-Frequency Approaches: Prospects and Challenges

Onyekachi Raymond, Yasmin Liu, Rishi Ranjan Pandey, Mary Jane McCarthy
article en
5 citations

Abstract

Despite the rapid growth in aptamer-based biosensor research, there remains a significant demand for aptasensors that operate without the need for sample preparation and calibration, to better facilitate real-world applications. Electrochemical aptamer-based (EAB) sensors, particularly those utilizing a dual-frequency, calibration-free approach, have shown promising advances toward commercialization. Single-use, disposable sensors represent a cost-effective solution for at-home and on-site point-of-care (POC) diagnostics. However, the development of these sensors presents unique challenges compared to <i>in vivo</i> monitoring and reusable platforms, with pronounced variations across sensors and batches. Motivated by these challenges, we have comprehensively investigated the dual-frequency, calibration-free approach, focusing on sensor-to-sensor and batch-to-batch variations. Our research explored the use of a nonresponsive frequency-based ratiometric method for detecting cocaine with laser-ablated, disposable EAB sensors. Additionally, to overcome the absence of nonresponsive frequencies in some aptasensors, we developed strategies to modify the aptamer structure and optimize operational conditions, effectively tailoring nonresponsive frequencies to allow for rapid result turnover. Moreover, we assessed the effects of various filter types on saliva pretreatment using liquid chromatography with tandem mass spectrometry (LCMS/MS) and developed a saliva collection workflow using an oral swab. This workflow and the disposable aptasensors developed herein achieved low μM sensitivity in saliva, with results obtainable in under 5 min, including saliva collection and processing. Furthermore, our findings indicate that certain food and drink residues in saliva can compromise sensor accuracy, highlighting an area for future refinement.

Analytical ChemistryVol. 97(9)
New Zealand Institute for Public Health and Forensic Science (NZ)
Ministry of Business, Innovation and Employment
Zero hunger
Openalex Percentile: Top 9%
Advanced Chemical Sensor Technologies
3.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.